Evidence map›Paper›PMID 26891218›Full record

SynthesisPloS one2016

Evaluation of a Rapid Point of Care Test for Detecting Acute and Established HIV Infection, and Examining the Role of Study Quality on Diagnostic Accuracy: A Bayesian Meta-Analysis.

Megan Smallwood, Rohit Vijh, Bénédicte Nauche, Bertrand Lebouché, Lawrence Joseph, Nitika Pant Pai

Abstract readEvaluation StudyMeta-Analysis
In one paragraph

Synthesis in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. The fourth generation AlereJournal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2017
    Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Megan SmallwoodDepartment of Epidemiology, Biostatistics and Occupational Health, McGill University, Montréal, Quebec, Canada.
Rohit VijhDivision of Clinical Epidemiology, Department of Medicine, McGill University Health Centre, Montreal, Quebec, Canada.
Bénédicte NaucheMedical Library, Royal Victoria Hospital, McGill University Health Centre, Montreal, Canada.
Bertrand LebouchéChronic Viral Illness Service, Research Institute of the McGill University Health Centre, Montreal, Canada.
Lawrence JosephDepartment of Epidemiology, Biostatistics and Occupational Health, McGill University, Montréal, Quebec, Canada.
Nitika Pant PaiDivision of Clinical Epidemiology, Department of Medicine, McGill University Health Centre, Montreal, Quebec, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFourth generation (Ag/Ab combination) point of care HIV tests like the FDA-approved Determine HIV1/2 Ag/Ab Combo test offer the promise of timely detection of acute HIV infection, relevant in the context of HIV control. However, a synthesis of their performance has not yet been done. In this meta-analysis we not only assessed device performance but also evaluated the role of study quality on diagnostic accuracy.

methodsTwo independent reviewers searched seven databases, including conferences and bibliographies, and independently extracted data from 17 studies. Study quality was assessed with QUADAS-2. Data on sensitivity and specificity (overall, antigen, and antibody) were pooled using a Bayesian hierarchical random effects meta-analysis model. Subgroups were analyzed by blood samples (serum/plasma vs. whole blood) and study designs (case-control vs. cross-sectional).

resultsThe overall specificity of the Determine Combo test was 99.1%, 95% credible interval (CrI) [97.3-99.8]. The overall pooled sensitivity for the device was at 88.5%, 95% [80.1-93.4]. When the components of the test were analyzed separately, the pooled specificities were 99.7%, 95% CrI [96.8-100] and 99.6%, 95% CrI [99.0-99.8], for the antigen and antibody components, respectively. Pooled sensitivity of the antibody component was 97.3%, 95% CrI [60.7-99.9], and pooled sensitivity for the antigen component was found to be 12.3%, 95% (CrI) [1.1-44.2]. No significant differences were found between subgroups by blood sample or study design. However, it was noted that many studies restricted their study sample to p24 antigen or RNA positive specimens, which may have led to underestimation of overall test performance. Detection bias, selection (spectrum) bias, incorporation bias, and verification bias impaired study quality.

conclusionsAlthough the specificity of all test components was high, antigenic sensitivity will merit from an improvement. Besides the accuracy of the device itself, study quality, also impacts the performance of the test. These factors must be kept in mind in future evaluations of an improved device, relevant for global scale up and implementation.

Indexed as

Point-of-Care TestingBayes TheoremHIV InfectionsHIV SeronegativityHIV SeropositivityHumansQuality Assurance, Health CareSensitivity and Specificity

Identifiers

PMID26891218
PMCPMC4758636

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.