ArticleBiotechnology and bioengineering2016
A reductionist metastasis-on-a-chip platform for in vitro tumor progression modeling and drug screening.
Article in Biotechnology and bioengineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 112 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
112 citing papers in PubMed, 1 synthesis or guideline pooled it, 222 citations in OpenAlex.
- 3D Printing Techniques and Their Applications to Organ-on-a-Chip Platforms: A Systematic Review.Sensors (Basel, Switzerland) · 2021Pooled it
- Synergistic innovation in organ-on-a-chip and organoid technologies: reshaping the future of disease modeling, drug development, and precision medicine.Protein & cell · 2026Review
- Review
- Cancer metastasisFrontiers in bioengineering and biotechnology · 2026Review
- The ethical aspects of human organ-on-chip models: A mapping review.Stem cell reports · 2025Review
- GABAergic signaling contributes to tumor cell invasion and poor overall survival in colorectal cancer.Oncogene · 2025Article
- From 2D to 3D and beyond: the evolution and impact of in vitro tumor models in cancer research.Nature methods · 2025Review
- Lung cancer intravasation-on-a-chip: Visualization and machine learning-assisted automatic quantification.Bioactive materials · 2025Article
- From lab to life: technological innovations in transforming cancer metastasis detection and therapy.Discover oncology · 2025Review
- The Role of the Tumor Microenvironment in Gastroenteropancreatic Neuroendocrine Tumors.International journal of molecular sciences · 2025Review
- Development of a Microphysiological System to Model Human Cancer Metastasis From the Colon to the Liver.Biotechnology and bioengineering · 2025Article
- Review
- The mechanopathology of the tumor microenvironment: detection techniques, molecular mechanisms and therapeutic opportunities.Frontiers in cell and developmental biology · 2025Review
- Targeted Cancer Therapy-on-A-Chip.Advanced healthcare materials · 2024Review
- RCAN1.4 regulates tumor cell engraftment and invasion in a thyroid cancer to lung metastasis-on-a-chip microphysiological system.Biofabrication · 2024Article
- A Synergistic Overview between Microfluidics and Numerical Research for Vascular Flow and Pathological Investigations.Sensors (Basel, Switzerland) · 2024Review
- Advancements in 3D In Vitro Models for Colorectal Cancer.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Bioengineered in vitro three-dimensional tumor models in endocrine cancers.Endocrine-related cancer · 2024Review
- State of the Art in 3D Culture Models Applied to Thyroid Cancer.Medicina (Kaunas, Lithuania) · 2024Review
- Patient-derived organoids: a promising tool for breast cancer research.Frontiers in oncology · 2024Review
52 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
Current animal and 2-D cell culture models employed in metastasis research and drug discovery remain poor mimics of human cancer physiology. Here we describe a "metastasis-on-a-chip" system allowing real time tracking of fluorescent colon cancer cells migrating from hydrogel-fabricated gut constructs to downstream liver constructs within a circulatory fluidic device system that responds to environmental manipulation and drug treatment. Devices consist of two chambers in which gut and liver constructs are housed independently, but are connected in series via circulating fluid flow. Constructs were biofabricated with a hyaluronic acid-based hydrogel system, capable of a variety of customizations, inside of which representative host tissue cells were suspended and metastatic colon carcinoma tumor foci were created. The host tissue of the constructs expressed normal epithelial markers, which the tumor foci failed to express. Instead, tumor regions lost membrane-bound adhesion markers, and expressed mesenchymal and proliferative markers, suggesting a metastatic phenotype. Metastatic tumor foci grew in size, eventually disseminating from the intestine construct and entering circulation, subsequently reaching in the liver construct, thus mimicking some of the migratory events observed during metastasis. Lastly, we demonstrated the ability to manipulate the system, including chemically modulating the hydrogel system mechanical properties and administering chemotherapeutic agents, and evaluated the effects of these parameters on invasive tumor migration. These results describe the capability of this early stage metastasis-on-a-chip system to model several important characteristics of human metastasis, thereby demonstrating the potential of the platform for making meaningful advances in cancer investigation and drug discovery. Biotechnol. Bioeng. 2016;113: 2020-2032. © 2016 Wiley Periodicals, Inc.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.