Evidence map›Paper›PMID 26887528›Full record

Trial reportMedical science monitor basic research2016

Preliminary Results From the C-Pulse OPTIONS HF European Multicenter Post-Market Study.

Antonia Schulz, Thomas Krabatsch, Jan D Schmitto, Roland Hetzer, Mirko Seidel, Pascal M Dohmen, Holger Hotz

Abstract readClinical TrialMulticenter Study
In one paragraph

Trial report in Medical science monitor basic research, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Soft robotic devices for cardiovascular medicine.Nature reviews. Cardiology · 2026
    Review
  2. Review
  3. Article
  4. Article
  5. Review
  6. Visit to intensive care of 2050.Intensive care medicine · 2017
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Antonia SchulzCardio Centrum Berlin, Academic Teaching Institution of Charité, Medical University Berlin, Berlin, Germany.
Thomas KrabatschDepartment of Cardiac Surgery, German Heart Center Berlin, Berlin, Germany.
Jan D SchmittoDepartment of Cardiac, Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
Roland HetzerCardio Centrum Berlin, Academic Teaching Institution of Charité, Medical University Berlin, Berlin, Germany.
Mirko SeidelDepartment of Cardiology, Unfallkrankenhaus Berlin, Academic Teaching Hospital of Charité, Medical University Berlin, Berlin, Germany.
Pascal M DohmenDepartment of Cardiovascular Surgery, Charité Hospital, Medical University Berlin, Berlin, Germany.
Holger HotzCardio Centrum Berlin, Academic Teaching Institution of Charité, Medical University Berlin, Berlin, Germany.
Charité - Universitätsmedizin Berlin · DEBerlin Heart (Germany) · DEMedizinische Hochschule Hannover · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND The C-Pulse System is an extra-aortic balloon counterpulsation device. It is used to treat patients with heart failure disease in NYHA functional class III or ambulatory class IV. MATERIAL AND METHODS We present preliminary site-reported 6-month data from 3 centers in Germany as part of the prospective observational post-market OPTIONS HF study. RESULTS Between May 2013 and March 2014, the C-Pulse System was implanted in 8 patients (7 male) with a mean age of 61.6±9.3 years. Four had ischemic and 4 had non-ischemic cardiomyopathy. No stroke, myocardial infarction, major bleeding, or major infection due to the device were reported. One patient developed non-device-related refractory tachycardia with worsening heart failure 12 h after surgery and underwent left ventricular assist device implantation. Within 6 months of observation, functional status improved from NYHA III to II in 5 patients, and 2 remained in NYHA III. Mean left ventricular ejection fraction increased from 24.3±7.9% to 44.5±4.5% (p<0.0001). Mean Kansas City Cardiomyopathy Questionnaire overall score improved from 28.6±19.1 to 59.1±22.5 (p=0.0183). Six-minute walk test was performed in 6 out of 7 patients at follow-up. The mean distance improved from 252.0±85.1 m to 279.2±87.5 m (p>0.05). One patient was weaned off the device after 6 months of support. CONCLUSIONS The C-Pulse System provides a therapeutic option for patients with moderate-to-severe heart failure and seems to improve quality of life and cardiac function over time.

Indexed as

CardiomyopathiesCounterpulsationFemaleGermanyHeart FailureHumansMaleMiddle AgedProduct Surveillance, PostmarketingProspective StudiesTreatment Outcome

Identifiers

PMID26887528
PMCPMC4792223
OpenAlexW2285041152

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.