Evidence map›Paper›PMID 26887376›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2016

Cyclic changes in area- and perimeter-derived effective dimensions of the aortic annulus measured with multislice computed tomography and comparison with metric intraoperative sizing.

Won-Keun Kim, Alexander Meyer, Helge Möllmann, Andreas Rolf, Susanne Möllmann, Johannes Blumenstein, Arnaud Van Linden, Christian W Hamm, Thomas Walther, Jörg Kempfert

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.7field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 19 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Ultrasonography of Hepatocellular Carcinoma: From Diagnosis to Prognosis.Journal of clinical and translational hepatology · 2024
    Review
  5. Review
  6. Article
  7. Article
  8. Article
  9. Transcatheter valve-in-valve implantation (VinV-TAVR) for failed surgical aortic bioprosthetic valves.Clinical research in cardiology : official journal of the German Cardiac Society · 2019
    Article
  10. Article
  11. Article
  12. The Pivotal Role of Imaging in TAVR Procedures.Current cardiology reports · 2018
    Review
  13. Article
  14. Right ventricular fistula post-TAVR: amenable to interventional closure treatment.Clinical research in cardiology : official journal of the German Cardiac Society · 2017
    Article
  15. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Won-Keun KimDepartment of Cardiology, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany. w.kim@kerckhoff-klinik.de.
Alexander MeyerDepartment of Cardiac Surgery, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Helge MöllmannDepartment of Cardiology, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Andreas RolfDepartment of Cardiology, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Susanne MöllmannDepartment of Cardiology, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Johannes BlumensteinDepartment of Cardiology, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Arnaud Van LindenDepartment of Cardiac Surgery, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Christian W HammDepartment of Cardiology, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Thomas WaltherDepartment of Cardiac Surgery, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Jörg KempfertDepartment of Cardiac Surgery, Kerckhoff Heart and Lung Center, Benekestrasse 2-8, 61231, Bad Nauheim, Germany.
Kerckhoff Klinik · DEUniversity of Giessen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsMultislice computed tomography (MSCT) is recommended for annular sizing prior to transcatheter aortic valve implantation (TAVI), but it remains unclear whether systolic or diastolic reconstructions should be used and whether the effective annular diameter should be derived by area or perimeter. In this study these different approaches were compared with intraoperative sizing.

methodsIn 52 patients who were evaluated but deemed unsuitable for TAVI, the annulus was measured during conventional surgery using metric sizers (AnnOp) and compared with MSCT measurements (cross-sectional diameter derived by area [AnnAsys, AnnAdia; AnnAmean = (AnnAsys + AnnAdia)/2] and perimeter (AnnPsys, AnnPdia) in systole and diastole). Furthermore, TAVI was simulated based on AnnOp and the impact of the various MSCT approaches on sizing strategy was determined.

resultsThe best agreement with AnnOp [mean difference (limits of agreement)] was shown for AnnAmean [0.03 mm (-1.9 to 1.96)], whereas the strongest deviation was noted for AnnPsys [-1.08 mm (-3.01 to 0.86)]. Mean differences between systole and diastole were significant but small: 0.82 mm (3.5 %) for area- and 0.81 mm (3.3 %) for perimeter-derived measurements. Simulation of TAVI revealed the least change of strategy for AnnAmean (76.9 %) as compared with AnnPsys (53.8 %); between AnnAsys and AnnAdia sizing would have been deviant in 17.3 % due to relatively large intraindividual cyclic differences.

conclusionsAnnAmean demonstrated the best agreement with AnnOp, whereas perimeter-derived measurements were somewhat overestimated. Despite a negligible average difference between systolic and diastolic annular values, in a subset of patients the intraindividual cyclic variability was relatively large and potentially of clinical impact.

Indexed as

Heart Valve ProsthesisMultidetector Computed TomographyProsthesis DesignAgedAged, 80 and overAortic ValveAortic Valve StenosisComputer SimulationDiastoleFemaleHeart Valve Prosthesis ImplantationHumansMaleObserver VariationPredictive Value of TestsRadiographic Image Interpretation, Computer-AssistedAnnulusAortic stenosisMSCTTAVI

Identifiers

PMID26887376
OpenAlexW2287827889

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.