ArticleIEEE transactions on bio-medical engineering2016
Scattering and Diffraction of Elastodynamic Waves in a Concentric Cylindrical Phantom for MR Elastography.
Article in IEEE transactions on bio-medical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Analytical solution for converging elliptic shear wave in a bounded transverse isotropic viscoelastic material with nonhomogeneous outer boundary.The Journal of the Acoustical Society of America · 2018Article
- Mechanical analysis of an axially symmetric cylindrical phantom with a spherical heterogeneity for MR elastography.Physics in medicine and biology · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
aimThe focus of this paper is to report on the design and construction of a multiply connected phantom for use in magnetic resonance elastography (MRE)-an imaging technique that allows for the noninvasive visualization of the displacement field throughout an object from externally driven harmonic motion-as well as its inverse modeling with a closed-form analytic solution which is derived herein from first principles.
methodsMathematically, the phantom is described as two infinite concentric circular cylinders with unequal complex shear moduli, harmonically vibrated at the exterior surface in a direction along their common axis. Each concentric cylinder is made of a hydrocolloid with its own specific solute concentration. They are assembled in a multistep process for which custom scaffolding was designed and built. A customized spin-echo-based MR elastography sequence with a sinusoidal motion-sensitizing gradient was used for data acquisition on a 9.4 T Agilent small-animal MR scanner. Complex moduli obtained from the inverse model are used to solve the forward problem with a finite-element method.
resultsBoth complex shear moduli show a significant frequency dependence (p 0.001) in keeping with previous work.
conclusionThe novel multiply connected phantom and mathematical model are validated as a viable tool for MRE studies. SIGNIFICANCE: On a small enough scale much of physiology can be mathematically modeled with basic geometric shapes, e.g., a cylinder representing a blood vessel. This study demonstrates the possibility of elegant mathematical analysis of phantoms specifically designed and carefully constructed for biomedical MRE studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.