Open access · hybridAbstract readValidation Study
In one paragraph

Article in Oxidative medicine and cellular longevity, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.7field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 32 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Cells · 2019
    Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Serena BrunduDepartment of Biomolecular Sciences, University of Urbino "Carlo Bo", 61029 Urbino, Italy.
Lucia NencioniDepartment of Public Health and Infectious Diseases, Pasteur Institute, Cenci-Bolognetti Foundation, "Sapienza" University of Rome, 00161 Rome, Italy.
Ignacio CelestinoDepartment of Public Health and Infectious Diseases, Pasteur Institute, Cenci-Bolognetti Foundation, "Sapienza" University of Rome, 00161 Rome, Italy.
Paolo ColuccioDepartment of Public Health and Infectious Diseases, Pasteur Institute, Cenci-Bolognetti Foundation, "Sapienza" University of Rome, 00161 Rome, Italy.
Anna Teresa PalamaraDepartment of Public Health and Infectious Diseases, Pasteur Institute, Cenci-Bolognetti Foundation, "Sapienza" University of Rome, 00161 Rome, Italy; San Raffaele Pisana Scientific Institute for Research, Hospitalization, and Health Care, 00163 Rome, Italy.
Mauro MagnaniDepartment of Biomolecular Sciences, University of Urbino "Carlo Bo", 61029 Urbino, Italy.ORCID 0000-0001-6456-6626
Alessandra FraternaleDepartment of Biomolecular Sciences, University of Urbino "Carlo Bo", 61029 Urbino, Italy.
Institut Pasteur · FRUniversity of Urbino · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A depletion of reduced glutathione (GSH) has been observed in pathological conditions and in aging. Measuring GSH in tissues using mouse models is an excellent way to assess GSH depletion and the potential therapeutic efficacy of drugs used to maintain and/or restore cellular redox potential. A high performance liquid chromatography (HPLC) method for the simultaneous determination of GSH and cysteine (Cys) in mouse organs was validated according to USA and European standards. The method was based on separation coupled with ultraviolet detection and precolumn derivatization with 5,5'-dithiobis-(2-nitrobenzoic acid) (DTNB). The required validation parameters, that are, selectivity, linearity, lower limit of quantification, precision, accuracy, recovery, and stability, were studied for spleen, lymph nodes, pancreas, and brain. The results showed that the lower limits of quantification were 0.313 μM and 1.25 μM for Cys and GSH, respectively. Intraday and interday precisions were less than 11% and 14%, respectively, for both compounds. The mean extraction recoveries of Cys and GSH from all organs were more than 93% and 86%, respectively. Moreover, the stability of both analytes during sample preparation and storage was demonstrated. The method was accurate, reliable, consistent, and reproducible and it was useful to determine Cys and GSH in the organs of different mouse strains.

Indexed as

AnimalsCalibrationChromatography, High Pressure LiquidChromatography, Reverse-PhaseCysteineFemaleGlutathioneLimit of DetectionMice, Inbred ICROrgan SpecificityReproducibility of ResultsCysteineGlutathione

Identifiers

PMID26885246
PMCPMC4739232
OpenAlexW2222474541

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked