Evidence map›Paper›PMID 26879647›Full record

ArticleAnalytical and bioanalytical chemistry2016

Quantification of a peptide standard using the intrinsic fluorescence of tyrosine.

George W Preston, David H Phillips

Open access · hybridAbstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.6field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

George W PrestonAnalytical & Environmental Sciences Division, MRC-PHE Centre for Environment & Health, King's College London, Franklin-Wilkins Building, 150 Stamford Street, London, SE1 9NH, UK.
David H PhillipsAnalytical & Environmental Sciences Division, MRC-PHE Centre for Environment & Health, King's College London, Franklin-Wilkins Building, 150 Stamford Street, London, SE1 9NH, UK. david.phillips@kcl.ac.uk.
King's College London · GB

Funding

Cancer Research UK 14329
6 · The paper itself

Abstract

Absolute quantification of peptides is typically achieved using amino acid analysis, elemental analysis or derivatisation chemistry. Impurities, if present, may be accounted for using analytical high-performance liquid chromatography (HPLC) with detection of the peptide bond ultraviolet (UV) absorbance. To do this, peak areas from a UV chromatogram are used to estimate percentage purity on a mass basis, and this purity value is used as a correction. However, because the approach assumes that UV absorbance is uniformly proportional to mass, the result may be only semi-quantitative. Here, an alternative approach involving HPLC with detection of intrinsic tyrosine fluorescence is described. The fluorescence properties of a 21-residue synthetic peptide corresponding to an S-carbamidomethylated tryptic fragment of human serum albumin were characterised, and a method involving quantification relative to a non-peptidic calibrant, N-acetyl-L-tyrosine ethyl ester, was established. The method was used to quantify the thiol form of the peptide, and the results were compared with a parallel analysis involving derivatisation of the same material with Ellman's reagent. When differences in fluorescence response (analyte versus calibrant) were accounted for, the measurements obtained via the two methods were in good agreement. Contributions from peptidic impurities were also considered, and their influence on the validity of the conclusions was evaluated. Despite some ambiguities introduced by the impurities, and the identification of some other potential sources of error, the results demonstrate that use of Tyr fluorescence is a promising solution to the challenging problem of absolute peptide quantification.

Indexed as

Chromatography, High Pressure LiquidFluorescenceLimit of DetectionPeptidesReference StandardsSpectrometry, Mass, Electrospray IonizationSpectrophotometry, UltravioletTyrosinePeptidesTyrosineAmino acids/peptidesFluorescence/luminescenceGenomics/proteomicsHPLC

Identifiers

PMID26879647
PMCPMC4799795
OpenAlexW2267567923

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked