Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector.

A Jain, H Takemoto, M D Silver, S V S Nagesh, C N Ionita, D R Bednarek, S Rudin

Open access · greenAbstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Clinical Micro-CT Empowered by Interior Tomography, Robotic Scanning, and Deep Learning.IEEE access : practical innovations, open solutions · 2020
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

A JainToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
H TakemotoToshiba Medical Research Institute, USA, Vernon Hills, IL.
M D SilverConsultant, Toshiba Medical Research Institute, USA, Vernon Hills, IL.
S V S NageshToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
C N IonitaToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
D R BednarekToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
S RudinToshiba Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY.
Toshiba (United States) · US

Funding

Micro-Radiographic Imager for Neuroovascular InterventionsR01EB002873 · NIBIB · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 2003 to 2015
$5.6M
MICRORADIOGRAPHIC IMAGER FOR NEUROVASCULAR INTERVENTIONR01NS038746 · NINDS · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI RUDIN, STEPHEN · 1999 to 2001
$793k
NIBIB NIH HHS R01 EB002873NINDS NIH HHS R01 NS038746
6 · The paper itself

Abstract

Cone beam computed tomography (CBCT) systems with rotational gantries that have standard flat panel detectors (FPD) are widely used for the 3D rendering of vascular structures using Feldkamp cone beam reconstruction algorithms. One of the inherent limitations of these systems is limited resolution (<3 lp/mm). There are systems available with higher resolution but their small FOV limits them to small animal imaging only. In this work, we report on region-of-interest (ROI) CBCT with a high resolution CMOS detector (75 μm pixels, 600 μm HR-CsI) mounted with motorized detector changer on a commercial FPD-based C-arm angiography gantry (194 μm pixels, 600 μm HL-CsI). A cylindrical CT phantom and neuro stents were imaged with both detectors. For each detector a total of 209 images were acquired in a rotational protocol. The technique parameters chosen for the FPD by the imaging system were used for the CMOS detector. The anti-scatter grid was removed and the incident scatter was kept the same for both detectors with identical collimator settings. The FPD images were reconstructed for the 10 cm x10 cm FOV and the CMOS images were reconstructed for a 3.84 cm × 3.84 cm FOV. Although the reconstructed images from the CMOS detector demonstrated comparable contrast to the FPD images, the reconstructed 3D images of the neuro stent clearly showed that the CMOS detector improved delineation of smaller objects such as the stent struts (~70 μm) compared to the FPD. Further development and the potential for substantial clinical impact are suggested.