Evidence map›Paper›PMID 26863580›Full record

ArticleInvestigative radiology2016

Comparison of Routine Brain Imaging at 3 T and 7 T.

Elisabeth Springer, Barbara Dymerska, Pedro Lima Cardoso, Simon Daniel Robinson, Christian Weisstanner, Roland Wiest, Benjamin Schmitt, Siegfried Trattnig

Open access · greenAbstract readComparative Study
In one paragraph

Article in Investigative radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 48 papers, 4 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
48citing papers in PubMed, 4 pooled it
7.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

48 citing papers in PubMed, 4 syntheses or guidelines pooled it, 104 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Review
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Enlarged perivascular spaces in the basal ganglia are associated with arteries not veins.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2024
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Advances in Technical Aspects of Deep Brain Stimulation Surgery.Stereotactic and functional neurosurgery · 2023
    Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 4 countries.

Elisabeth SpringerFrom the *High Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria; †Support Center of Advanced Neuroimaging, University Institute for Diagnostic and Interventional Neuroradiology, University Hospital Bern and Inselspital, University of Bern, Bern, Switzerland; ‡Siemens Healthcare Pty Ltd Australia, Imaging and Therapy Systems, Magnetic Resonance, Macquarie Park, New South Wales, Australia; §Siemens Healthcare, Erlangen, Germany; and ∥CD Laboratory for Molecular Clinical MR Imaging, Vienna, Austria.
Barbara Dymerska
Pedro Lima Cardoso
Simon Daniel Robinson
Christian Weisstanner
Roland Wiest
Benjamin Schmitt
Siegfried Trattnig
Medical University of Vienna · ATSiemens Healthcare (Germany) · DEUniversity Hospital of Bern · CHUniversity of Bern · CH

Funding

Austrian Science Fund FWF KLI 264
6 · The paper itself

Abstract

objectiveThe aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating disease, gliomas, cerebrovascular disease, and epilepsy, with comparable sequence protocols and acquisition times at 3 T and at 7 T. MATERIALS AND

methodsTen healthy volunteers and 4 subgroups of 40 patients in total underwent comparable magnetic resonance protocols with standard diffusion-weighted imaging, 2D and 3D turbo spin echo, 2D and 3D gradient echo and susceptibility-weighted imaging of the brain (10 sequences) at 3 T and 7 T. The subgroups comprised patients with either lesional (n = 5) or nonlesional (n = 4) epilepsy, intracerebral tumors (n = 11), demyelinating disease (n = 11) (relapsing-remitting multiple sclerosis [MS, n = 9], secondary progressive MS [n = 1], demyelinating disease not further specified [n = 1]), or chronic cerebrovascular disorders [n = 9]). For quantitative analysis, SNR and CNR were determined. For a semiquantitative assessment of the diagnostic confidence, a 10-point scale diagnostic confidence score (DCS) was applied. Two experienced radiologists with additional qualification in neuroradiology independently assessed, blinded to the field strength, 3 pathology-specific imaging criteria in each of the 4 disease groups and rated their diagnostic confidence. The overall image quality was semiquantitatively assessed using a 4-point scale taking into account whether diagnostic decision making was hampered by artifacts or not.

resultsWithout correction for spatial resolution, SNR was higher at 3 T except in the T2 SPACE 3D, DWI single shot, and DIR SPACE 3D sequences. The SNR corrected by the ratio of 3 T/7 T voxel sizes was higher at 7 T than at 3 T in 10 of 11 sequences (all except for T1 MP2RAGE 3D).In CNR, there was a wide variation between sequences and patient cohorts, but average CNR values were broadly similar at 3 T and 7 T.DCS values for all 4 pathologic entities were higher at 7 T than at 3 T. The DCS was significantly higher at 7 T for diagnosis and exclusion of cortical lesions in vascular disease. A tendency to higher DCS at 7 T for cortical lesions in MS was observed, and for the depiction of a central vein and iron deposits within MS lesions. Despite motion artifacts, DCS values were higher at 7 T for the diagnosis and exclusion of hippocampal sclerosis in mesial temporal lobe epilepsy (improved detection of the hippocampal subunits). Interrater agreement was 69.7% at 3 T and 93.3% at 7 T. There was no significant difference in the overall image quality score between 3 T and 7 T taking into account whether diagnostic decision making was hampered by artifacts or not.

conclusionsUltra-high-field magnetic resonance imaging at 7 T compared with 3 T yielded an improved diagnostic confidence in the most frequently encountered neurologic disorders. Higher spatial resolution and contrast were identified as the main contributory factors.

Indexed as

AdultArtifactsBrainBrain DiseasesDiffusion Magnetic Resonance ImagingFemaleHumansImaging, Three-DimensionalMagnetic Resonance ImagingMaleMiddle AgedNeuroimagingSignal-To-Noise RatioYoung Adult

Identifiers

PMID26863580
PMCPMC5704893
OpenAlexW2263159151

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.