Evidence map›Paper›PMID 26862713›Full record

ArticleThe Analyst2016

Electrochemical detection of peroxynitrite using hemin-PEDOT functionalized boron-doped diamond microelectrode.

Serban F Peteu, Brandon W Whitman, James J Galligan, Greg M Swain

Abstract read
In one paragraph

Article in The Analyst, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. GNP-CeOMikrochimica acta · 2021
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Serban F PeteuDepartment of Chemistry and the Neuroscience Program, 578 S. Shaw Lane. and Michigan State University, East Lansing, Michigan 48824-1322, USA. swain@chemistry.msu.edu and Department of Chemical Engineering and Materials Science, 428 S. Shaw Lane and Michigan State University, East Lansing, Michigan 48824-1226, USA.
Brandon W WhitmanDepartment of Chemistry and the Neuroscience Program, 578 S. Shaw Lane. and Michigan State University, East Lansing, Michigan 48824-1322, USA. swain@chemistry.msu.edu.
James J GalliganDepartment of Pharmacology and Toxicology, and the Neuroscience Program, B440 Life Sciences Building and Michigan State University, East Lansing, MI 48824-1317, USA.
Greg M SwainDepartment of Chemistry and the Neuroscience Program, 578 S. Shaw Lane. and Michigan State University, East Lansing, Michigan 48824-1322, USA. swain@chemistry.msu.edu.

Funding

SIGNALING MECHANISMS IN ARTERIES AND VEINS IN HYPERTENSIONP01HL070687 · NHLBI · MICHIGAN STATE UNIVERSITY · PI WATTS, STEPHANIE W · 2003 to 2019
$22.8M
Purinergic neurotransmission in the gutR01DK094932 · NIDDK · MICHIGAN STATE UNIVERSITY · PI GALLIGAN, JAMES J. · 2012 to 2016
$1.5M
NHLBI NIH HHS P01 HL070687NIDDK NIH HHS R01 DK094932
6 · The paper itself

Abstract

Peroxynitrite is a potent nitroxidation agent and highly reactive metabolite, clinically correlated with a rich pathophysiology. Its sensitive and selective detection is challenging due to its high reactivity and short sub-second lifetime. Boron-doped diamond (BDD) microelectrodes have attracted interest because of their outstanding electroanalytical properties that include a wide working potential window and enhanced signal-to-noise ratio. Herein, we report on the modification of a BDD microelectrode with an electro-polymerized film of hemin and polyethylenedioxythiophene (PEDOT) for the purpose of selectively quantifying peroxynitrite. The nanostructured modified polymer layer was characterized by Raman spectroscopy and scanning electron microscopy (SEM). The electrochemical response to peroxynitrite was studied by voltammetry and time-based amperometry. The measured detection limit was 10 ± 0.5 nM (S/N = 3), the sensitivity was 4.5 ± 0.5 nA nM(-1) and the response time was 3.5 ± 1 s. The hemin-PEDOT BDD sensors exhibited a response variability of 5% or less (RSD). The stability of the sensors after a 20-day storage in 0.1 M PB (pH 7.4) at 4 °C was excellent as at least 93% of the initial response to 50 nM PON was maintained. The presence of PEDOT was correlated with a sensitivity increase.

Indexed as

BoronBridged Bicyclo Compounds, HeterocyclicDiamondElectrochemistryHeminLimit of DetectionMicroelectrodesPeroxynitrous AcidPolymersSpectrum Analysis, RamanTime FactorsBoronBridged Bicyclo Compounds, HeterocyclicDiamondHeminPeroxynitrous Acidpoly(3,4-ethylene dioxythiophene)Polymers

Identifiers

PMID26862713
PMCPMC4777311

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.