ArticleEar and hearing
A Binaural Cochlear Implant Sound Coding Strategy Inspired by the Contralateral Medial Olivocochlear Reflex.
Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 64 citations in OpenAlex.
- The Effects of Broadband Elicitor Duration on Transient-Evoked Otoacoustic Emissions and a Psychoacoustic Measure of Gain Reduction.Journal of the Association for Research in Otolaryngology : JARO · 2025Article
- A deep learning framework for understanding cochlear implants.bioRxiv : the preprint server for biology · 2025Article
- Binaural audio frontend processing for cochlear implants inspired by the medial olivocochlear reflex.Frontiers in neuroscience · 2025Article
- The effects of broadband elicitor duration on a psychoacoustic measure of cochlear gain reduction.The Journal of the Acoustical Society of America · 2023Article
- Magnitude of the contralateral efferent olivocochlear effect as a function of the frequency.Journal of otology · 2022Article
- Direct Cochlear Recordings in Humans Show a Theta Rhythmic Modulation of Auditory Nerve Activity by Selective Attention.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2022Article
- Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update.Journal of the Association for Research in Otolaryngology : JARO · 2021Review
- Understanding degraded speech leads to perceptual gating of a brainstem reflex in human listeners.PLoS biology · 2021Article
- The effect of broadband elicitor laterality on psychoacoustic gain reduction across signal frequency.The Journal of the Acoustical Society of America · 2021Article
- The role of the medial olivocochlear reflex in psychophysical masking and intensity resolution in humans: a review.Journal of neurophysiology · 2021Review
- Adaptation to Noise in Human Speech Recognition Depends on Noise-Level Statistics and Fast Dynamic-Range Compression.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2020Article
- The role of efferents in human auditory development: efferent inhibition predicts frequency discrimination in noise for children.Journal of neurophysiology · 2020Article
- Changing stimulation patterns can change the broadness of contralateral masking functions for bilateral cochlear implant users.Hearing research · 2018Article
- Adaptation to Noise in Human Speech Recognition Unrelated to the Medial Olivocochlear Reflex.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2018Article
- Temporal Effects on Monaural Amplitude-Modulation Sensitivity in Ipsilateral, Contralateral and Bilateral Noise.Journal of the Association for Research in Otolaryngology : JARO · 2018Article
- Olivocochlear Efferents in Animals and Humans: From Anatomy to Clinical Relevance.Frontiers in neurology · 2018Review
- Article
- Article
- Coherent Coding of Enhanced Interaural Cues Improves Sound Localization in Noise With Bilateral Cochlear Implants.Trends in hearingArticle
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesIn natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources.
designPairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased/increased dynamically (so that output levels dropped/increased) with increases/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors.
resultsIn both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy.
conclusionsThe MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.