Evidence map›Paper›PMID 26862711›Full record

ArticleEar and hearing

A Binaural Cochlear Implant Sound Coding Strategy Inspired by the Contralateral Medial Olivocochlear Reflex.

Enrique A Lopez-Poveda, Almudena Eustaquio-Martín, Joshua S Stohl, Robert D Wolford, Reinhold Schatzer, Blake S Wilson

Open access · hybridAbstract read
In one paragraph

Article in Ear and hearing. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
3.7field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 64 citations in OpenAlex.

  1. Article
  2. A deep learning framework for understanding cochlear implants.bioRxiv : the preprint server for biology · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Direct Cochlear Recordings in Humans Show a Theta Rhythmic Modulation of Auditory Nerve Activity by Selective Attention.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2022
    Article
  7. Cochlear Implant Research and Development in the Twenty-first Century: A Critical Update.Journal of the Association for Research in Otolaryngology : JARO · 2021
    Review
  8. Article
  9. Article
  10. Review
  11. Adaptation to Noise in Human Speech Recognition Depends on Noise-Level Statistics and Fast Dynamic-Range Compression.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2020
    Article
  12. Article
  13. Article
  14. Adaptation to Noise in Human Speech Recognition Unrelated to the Medial Olivocochlear Reflex.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2018
    Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 2 countries.

Enrique A Lopez-Poveda1Instituto de Neurociencias de Castilla y León, 2Instituto de Investigación Biomédica de Salamanca, 3Departamento de Cirugía, Facultad de Medicina, Universidad de Salamanca, Salamanca, Spain; 4USA Laboratory, MED-EL GmbH, Innsbruck, Austria; 5Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina, USA; 6Institute of Mechatronics, University of Innsbruck, Innsbruck, Austria; 7Department of Surgery, Duke University Medical Center, Durham, North Carolina, USA; 8Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.
Almudena Eustaquio-Martín
Joshua S Stohl
Robert D Wolford
Reinhold Schatzer
Blake S Wilson
Duke University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesIn natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources.

designPairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased/increased dynamically (so that output levels dropped/increased) with increases/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors.

resultsIn both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy.

conclusionsThe MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids.

Indexed as

Cochlear ImplantationCochlear ImplantsReflexSpeech PerceptionDeafnessFemaleHumansMaleSoftware

Identifiers

PMID26862711
PMCPMC4894785
OpenAlexW2312399799

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.