Evidence map›Paper›PMID 26859896›Full record

ArticlePloS one2016

Manual Ventilation and Sustained Lung Inflation in an Experimental Model: Influence of Equipment Type and Operator's Training.

Cristiane do Prado, Ruth Guinsburg, Maria Fernanda Branco de Almeida, Renata Suman Mascaretti, Luciana Assis Vale, Luciana Branco Haddad, Celso Moura Rebello

Abstract readComparative StudyEvaluation Study
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cristiane do PradoDepartment of Pediatrics, School of Medicine, University of Sao Paulo, Sao Paulo, Sao Paulo, Brazil.
Ruth GuinsburgBrazilian Society of Pediatrics, Neonatal Resuscitation Program, Sao Paulo, Sao Paulo, Brazil.
Maria Fernanda Branco de AlmeidaBrazilian Society of Pediatrics, Neonatal Resuscitation Program, Sao Paulo, Sao Paulo, Brazil.
Renata Suman MascarettiDepartment of Pediatrics, Hospital da Vila Santa Catarina, Sao Paulo, Sao Paulo, Brazil.
Luciana Assis ValeDepartment of Pediatrics, Hospital Israelita Albert Einstein, Sao Paulo, Sao Paulo, Brazil.
Luciana Branco HaddadDepartment of Pediatrics, Hospital Israelita Albert Einstein, Sao Paulo, Sao Paulo, Brazil.
Celso Moura RebelloDepartment of Pediatrics, School of Medicine, University of Sao Paulo, Sao Paulo, Sao Paulo, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimTo compare the influence of devices for manual ventilation and individual experience on the applied respiratory mechanics and sustained lung inflation.

methodsA total of 114 instructors and non-instructors from the Neonatal Resuscitation Program of the Brazilian Society of Pediatrics participated in this study. Participants ventilated an intubated manikin. To evaluate respiratory mechanics and sustained lung inflation parameters, a direct comparison was made between the self-inflating bag and the T-shaped resuscitator (T-piece), followed by an analysis of the effectiveness of the equipment according to the participants' education and training.

resultsA difference between equipment types was observed for the tidal volume, with a median (interquartile range) of 28.5 mL (12.6) for the self-inflating bag and 20.1 mL (8.4) for the T-piece in the instructor group and 31.6 mL (14) for the self-inflating bag and 22.3 mL (8.8) for the T-piece in the non-instructor group. Higher inspiratory time values were observed with the T-piece in both groups of professionals, with no significant difference between them. The operator's ability to maintain the target pressure over the 10 seconds of sustained lung inflation was evaluated using the area under the pressure-time curve and was 1.7-fold higher with the use of the T-piece. Inspiratory pressure and mean airway pressure applied during sustained lung inflation were greater with the self-inflating bag, as evaluated between the beginning and the end of the procedure.

conclusionThe T-piece resulted in lower tidal volume and higher inspiratory time values, irrespective of the operator's experience, and increased the ease of performing the sustained lung inflation maneuver, as demonstrated by the maintenance of target pressure for the desired period and a higher mean airway pressure than that obtained using the self-inflating bag.

Indexed as

BrazilEquipment DesignHumansInfant, NewbornManikinsModels, BiologicalModels, TheoreticalPositive-Pressure RespirationRespiration, ArtificialRespiratory MechanicsResuscitationTidal Volume

Identifiers

PMID26859896
PMCPMC4747546

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.