Evidence map›Paper›PMID 26858807›Full record

ArticleBiomicrofluidics2016

A highly efficient bead extraction technique with low bead number for digital microfluidic immunoassay.

Cheng-Yeh Huang, Po-Yen Tsai, I-Chin Lee, Hsin-Yun Hsu, Hong-Yuan Huang, Shih-Kang Fan, Da-Jeng Yao, Cheng-Hsien Liu, Wensyang Hsu

Abstract read
In one paragraph

Article in Biomicrofluidics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Cheng-Yeh HuangDepartment of Mechanical Engineering, National Chiao Tung University , Hsinchu, Taiwan.ORCID 0000-0001-7865-1020
Po-Yen TsaiDepartment of Mechanical Engineering, National Chiao Tung University , Hsinchu, Taiwan.
I-Chin LeeDepartment of Applied Chemistry, National Chiao Tung University , Hsinchu, Taiwan.
Hsin-Yun HsuDepartment of Applied Chemistry, National Chiao Tung University , Hsinchu, Taiwan.
Hong-Yuan Huang
Shih-Kang FanDepartment of Mechanical Engineering, National Taiwan University , Taipei, Taiwan.
Cheng-Hsien LiuDepartment of Power Mechanical Engineering, National Tsing Hua University , Hsinchu, Taiwan.
Wensyang HsuDepartment of Mechanical Engineering, National Chiao Tung University , Hsinchu, Taiwan.ORCID 0000-0002-0189-9578

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Here, we describe a technique to manipulate a low number of beads to achieve high washing efficiency with zero bead loss in the washing process of a digital microfluidic (DMF) immunoassay. Previously, two magnetic bead extraction methods were reported in the DMF platform: (1) single-side electrowetting method and (2) double-side electrowetting method. The first approach could provide high washing efficiency, but it required a large number of beads. The second approach could reduce the required number of beads, but it was inefficient where multiple washes were required. More importantly, bead loss during the washing process was unavoidable in both methods. Here, an improved double-side electrowetting method is proposed for bead extraction by utilizing a series of unequal electrodes. It is shown that, with proper electrode size ratio, only one wash step is required to achieve 98% washing rate without any bead loss at bead number less than 100 in a droplet. It allows using only about 25 magnetic beads in DMF immunoassay to increase the number of captured analytes on each bead effectively. In our human soluble tumor necrosis factor receptor I (sTNF-RI) model immunoassay, the experimental results show that, comparing to our previous results without using the proposed bead extraction technique, the immunoassay with low bead number significantly enhances the fluorescence signal to provide a better limit of detection (3.14 pg/ml) with smaller reagent volumes (200 nl) and shorter analysis time (<1 h). This improved bead extraction technique not only can be used in the DMF immunoassay but also has great potential to be used in any other bead-based DMF systems for different applications.

Identifiers

PMID26858807
PMCPMC4714987

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.