ArticleJournal of magnetic resonance imaging : JMRI2016
Assessment of renal function using intravoxel incoherent motion diffusion-weighted imaging and dynamic contrast-enhanced MRI.
Article in Journal of magnetic resonance imaging : JMRI, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed, 48 citations in OpenAlex.
- The role of diffusion-weighted MRI in biological image-guided radiation therapy: a roadmap.Physics in medicine and biology · 2026Review
- Multimodal Magnetic Resonance Imaging in Diabetic Kidney Disease: From Pathophysiological Insights to Clinical Applications.Diagnostics (Basel, Switzerland) · 2026Review
- Cardiac-Gated Diffusion-Weighted Magnetic Resonance Imaging Assessment of Kidney Function in Patients With Kidney Cancer.Kidney international reports · 2026Article
- Streamlined calculation of kidney function using dynamic contrast-enhanced MRI with population-based arterial input function and a whole-kidney model.European radiology experimental · 2026Article
- Quantitative Parameters Derived Using the Biexponential and Stretched Exponential Models for the Detection of Early Renal Impairment in Chronic Kidney Disease.Current medical imaging · 2025Article
- Evaluation of Renal Perfusion: A Comparative Study between Intravoxel Incoherent Motion (IVIM) Imaging and Arterial Spin Labeling (ASL) to Assess Renal Blood Flow in Rodents.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2025Article
- Grading of clear cell renal cell carcinoma using diffusion MRI with a multimodal apparent diffusion model.Frontiers in oncology · 2025Article
- Tri- and bi-exponential diffusion analyses of the kidney: effect of respiratory-controlled acquisition on diffusion parameters.Radiological physics and technology · 2023Article
- Magnetic Resonance Imaging in Clinical Trials of Diabetic Kidney Disease.Journal of clinical medicine · 2023Review
- Intravoxel incoherent motion diffusion-weighted MRI of renal parenchyma and its clinical significance in patients with untreated acute leukemia: a pilot study.Abdominal radiology (New York) · 2023Article
- Preliminary study on intravoxel incoherent motion imaging and diffusion kurtosis imaging based on magnetic resonance imaging of normal kidneys in children.Translational pediatrics · 2022Article
- Magnetic resonance image compilation sequence to quantitatively detect active sacroiliitis with axial spondyloarthritis.Quantitative imaging in medicine and surgery · 2022Article
- Assessment of kidney function in chronic kidney disease by combining diffusion tensor imaging and total kidney volume.International urology and nephrology · 2022Article
- Intravoxel incoherent motion to differentiate spinal metastasis: A pilot study.Frontiers in oncology · 2022Article
- Noninvasive assessment of kidney dysfunction in children by using blood oxygenation level-dependent MRI and intravoxel incoherent motion diffusion-weighted imaging.Insights into imaging · 2021Article
- Evaluation of Radiographic Contrast-Induced Nephropathy by Functional Diffusion Weighted Imaging.Journal of clinical medicine · 2021Article
- Validation of multiparametric MRI by histopathology after nephrectomy: a case study.Magma (New York, N.Y.) · 2021Article
- Retrospective Distortion and Motion Correction for Free-Breathing DW-MRI of the Kidneys Using Dual-Echo EPI and Slice-to-Volume Registration.Journal of magnetic resonance imaging : JMRI · 2021Article
- Multiparametric Renal MRI: An Intrasubject Test-Retest Repeatability Study.Journal of magnetic resonance imaging : JMRI · 2021Article
- Renal Diffusion-Weighted Imaging in Healthy Dogs: Reproducibility, Test-Retest Repeatability, and Selection of the Optimal b-value Combination.Frontiers in veterinary science · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 2 countries.
Funding
Abstract
purposeTo assess the correlation between each of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in renal parenchyma with renal function, in a cohort of patients with chronic liver disease. MATERIALS AND
methodsThirty patients with liver disease underwent abdominal MRI at 1.5T, including a coronal respiratory-triggered IVIM-DWI sequence and a coronal 3D FLASH DCE-MRI acquisition. Diffusion signals in the renal cortex and medulla were fitted to the IVIM model to estimate the diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF). The apparent diffusion coefficient (ADC) was calculated using all b-values. The glomerular filtration rate (GFR), cortical and medullary renal plasma flow (RPF), mean transit times (MTT) of vascular and tubular compartments and the whole kidney, were calculated from DCE-MRI data by fitting to a three-compartment model. The estimated GFR (eGFR) was calculated from serum creatinine measured 30 ± 27 days of MRI.
resultsADC, PF, and RPF were significantly higher in renal cortex vs. medulla (P < 10(-5) ). DCE-MRI GFR significantly correlated with, but underestimated, eGFR (Spearman's r/P = 0.49/0.01). IVIM-DWI parameters were not significantly correlated with eGFR. DCE-MRI GFR correlated weakly with D (cortex, r/P = 0.3/0.03; medulla r/P = 0.27/0.05) and ADC (cortex r/P = 0.28/0.04; medulla r/P = 0.34/0.01). Weak correlations were observed for pooled cortical and medullar RPF with PF (r/P = 0.32/10(-3) ) and with ADC (r/P = 0.29/0.0025). Significant negative correlations were observed for vascular MTT with cortical D* (r/P = -0.38/0.004) and D*×PF (r/P = -0.34/0.01).
conclusionThe weak correlations between renal IVIM and DCE-MRI perfusion parameters imply that these functional measures could be complementary. J. Magn. Reson. Imaging 2016;44:317-326.