Evidence map›Paper›PMID 26854148›Full record

ArticleDiagnostics (Basel, Switzerland)2015

A Novel Point-of-Care Biomarker Recognition Method: Validation by Detecting Marker for Diabetic Nephropathy.

Sahana Pentyala, John Muller, Thomas Tumillo, Avijit Roy, Pooja Mysore, Srinivas Pentyala

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 44% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Sahana PentyalaDepartment of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA. sahana.pentyala@stonybrook.edu.
John MullerDepartment of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA. jmuller018@gmail.com.
Thomas TumilloDepartment of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA. tomtumillo@gmail.com.
Avijit RoyDepartment of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA. aviroy23@yahoo.com.
Pooja MysoreDepartment of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA. mysorp@gmail.com.
Srinivas PentyalaDepartment of Anesthesiology, Stony Brook Medical Center, Stony Brook, New York, NY 11794-8480, USA. srinivas.pentyala@stonybrook.edu.
Stony Brook Medicine · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Biological fluid collection to identify and analyze different disease markers is a routine and normal procedure in health care settings. Body fluids are as varied as urine, blood, mucus, cerebrospinal fluid (CSF), tears, semen, etc. The volumes of the collected fluids range from micro liters (e.g., tears, CSF) to tens and hundreds of milliliters (blood, urine, etc.). In some manifestations, a disease marker (particularly protein markers) can occur in trace amounts, yet the fluids collected are in large volumes. To identify these trace markers, cumbersome methods, expensive instruments, and trained personnel are required. We developed an easy method to rapidly capture, concentrate, and identify protein markers in large volumes of test fluids. This method involves the utilization of two antibodies recognizing two different epitopes of the protein biomarker. Antibody-1 helps to capture and concentrate the biomarker and Antibody-2 adsorbed or conjugated to nanogold beads will detect the biomarker. This method was validated in capturing and detecting lipocalin type prostaglandin-D2 synthase, a marker in urine that implicates diabetic nephropathy. A one-step collection, concentration, and detection device was designed based on this method. This device can replace many of the normal body fluid collection devices such as tubes and containers. A one-step fluid collection and biomarker capture and concentration device for rapid diagnosis of diseases has tremendous advantage in terms of cost and providing timely results.

Indexed as

antibodybiomarkerdiabetic nephropathypoint-of-care

Identifiers

PMID26854148
PMCPMC4665592
OpenAlexW1991380734

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.