Image quality, radiation dose and diagnostic accuracy of 70 kVp whole brain volumetric CT perfusion imaging: a preliminary study.

Xiao Kun Fang, Qian Qian Ni, U Joseph Schoepf, Chang Sheng Zhou, Guo Zhong Chen, Song Luo, Stephen R Fuller, Carlo N De Cecco, Long Jiang Zhang, Guang Ming Lu

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in European radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Xiao Kun FangDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
Qian Qian NiDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
U Joseph SchoepfDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
Chang Sheng ZhouDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
Guo Zhong ChenDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
Song LuoDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China.
Stephen R FullerDivision of Cardiovascular Imaging, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC, 29425, USA.
Carlo N De CeccoDivision of Cardiovascular Imaging, Medical University of South Carolina, Ashley River Tower, MSC 226, 25 Courtenay Dr, Charleston, SC, 29425, USA.
Long Jiang ZhangDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China. kevinzhlj@163.com.
Guang Ming LuDepartment of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu, 210002, China. cjr.luguangming@vip.163.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate image quality and diagnostic accuracy for acute infarct detection and radiation dose of 70 kVp whole brain CT perfusion (CTP) and CT angiography (CTA) reconstructed from CTP source data.

methodsPatients were divided into three groups (n = 50 each): group A, 80 kVp, 21 scanning time points; groups B, 70 kVp, 21 scanning time points; group C, 70 kVp, 17 scanning time points. Objective and subjective image quality of CTP and CTA were compared. Diagnostic accuracy for detecting acute infarct and cerebral artery stenosis ≥ 50 % was calculated for CTP and CTA with diffusion weighted imaging and digital subtraction angiography as reference standards. Effective radiation dose was compared.

resultsThere were no differences in any perfusion parameter value between three groups (P > 0.05). No difference was found in subjective image quality between three groups (P > 0.05). Diagnostic accuracy for detecting acute infarct and vascular stenosis showed no difference between three groups (P > 0.05). Compared with group A, radiation doses of groups B and C were decreased by 28 % and 37 % (both P < 0.001), respectively.

conclusionCompared with 80 kVp protocol, 70 kVp brain CTP allows comparable vascular and perfusion assessment and lower radiation dose while maintaining high diagnostic accuracy in detecting acute infarct. KEY POINTS: • 70 kVp whole brain CTP can provide diagnostic image quality. • 70 kVp CTP diagnostic accuracy was maintained vs. 80 kVp protocol. • 70 kVp CTP radiation doses were lower than 80 kVp protocol.

Indexed as

BrainCerebral Arterial DiseasesCerebral InfarctionComputed Tomography AngiographyCone-Beam Computed TomographyConstriction, PathologicFemaleHumansMagnetic Resonance AngiographyMaleMiddle AgedPerfusion ImagingRadiation DosageRadiographic Image Interpretation, Computer-AssistedTomography, Spiral ComputedCT angiographyCT perfusionLow tube voltageRadiation doseStroke