Evidence map›Paper›PMID 26848394›Full record

ArticleOpen heart

Did the use of the Guideliner V2(TM) guide catheter extension increase complications? A review of the incidence of complications related to the use of the V2 catheter, the influence of right brachiocephalic arterial anatomy and the redesign of the V3(TM) Guideliner and clinical outcomes.

Mohammad Alkhalil, Alison Smyth, Simon J Walsh, Conor McQuillan, Mark S Spence, Colum G Owens, Colm G Hanratty

Open access · goldAbstract read
In one paragraph

Article in Open heart. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 13 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Mohammad AlkhalilCardiology Department , Belfast City Hospital , Belfast , UK.
Alison SmythCardiology Department , Belfast City Hospital , Belfast , UK.
Simon J WalshCardiology Department , Belfast City Hospital , Belfast , UK.
Conor McQuillanCardiology Department , Royal Victoria Hospital , Belfast , UK.
Mark S SpenceCardiology Department , Royal Victoria Hospital , Belfast , UK.
Colum G OwensCardiology Department , Royal Victoria Hospital , Belfast , UK.
Colm G HanrattyCardiology Department , Belfast City Hospital , Belfast , UK.
Belfast City Hospital · GBUniversity of Ulster · GBRoyal Victoria Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveWe sought to investigate the incidence of complications associated with V2 Guideliner, understand the mechanisms and evaluate the impact of alterations made to the V3 Guideliner.

methodsRetrospective analysis of consecutive cases employing V2 Guideliner from two university teaching hospitals. Complications were identified, analysed and classified into major versus minor ones. To understand the potential anatomical mechanism of these complications, analysis of normal great vessel anatomy was undertaken in separate cohort of patients undergoing cardiac catheterisation via right radial approach. Further analysis of consecutive cases employing V3 Gudieliner took place and the incidence of complications were compared between V2 and V3 groups.

resultsTotal of 188 cases of V2 Guideliner use were identified. One major complication was reported (coronary dissection). Proximal collar interaction and stent damage occurred in 19 cases (10%). Anatomical data suggest that extending the V2 Guideliner tubing sited the proximal collar of the device in the brachiocephalic/subclavian artery, a potential site of tortuosity and potential cause of the Guideliner proximal collar-stent interaction. Further analysis of 124 cases of V3 Guideliner use demonstrated no cases with proximal collar-stent interactions, one case of longitudinal stent deformation and two incidents of stent interaction with the distal edge of the V3 Guideliner.

conclusionsWe have demonstrated a higher incidence of V2 Guideliner complications compared to previous series. The change in design of the V2 Guideliner was a likely contributor but the modifications with V3 Guideliner appear to have ameliorated this issue.

Indexed as

complex lesionCORONARY ARTERY DISEASEGuidelinerpercutaneous coronary interventionSubclavian artery

Identifiers

PMID26848394
PMCPMC4731838
OpenAlexW2255072956

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.