Characterization of attenuation and respiratory motion artifacts and their influence on SPECT MP image evaluation using a dynamic phantom assembly with variable cardiac defects.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Quantitative imaging: systematic review of perfusion/flow phantoms.European radiology experimental · 2020Pooled it
- Investigation of Attenuation Correction Methods for Dual-Gated Single Photon Emission Computed Tomography (DG-SPECT).Bioengineering (Basel, Switzerland) · 2025Article
- Validation of advanced hybrid SPECT/CT system using dynamic anthropomorphic cardiac phantom.Annals of nuclear medicine · 2024Article
- Anthropomorphic cardiac phantom for dynamic SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023Article
- A moving liver phantom in an anthropomorphic thorax for SPECT MP imaging.Physical and engineering sciences in medicine · 2022Article
- A new cardiac phantom for dynamic SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Inter-reader variability of SPECT MPI readings in low- and middle-income countries: Results from the IAEA-MPI Audit Project (I-MAP).Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020Article
- Have SPECT artifacts breathed their last?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017Article
- Quantitative analysis of multiple biokinetic models using a dynamic water phantom: A feasibility study.Bioengineered · 2016Article
Corrections and comments
- Commented on by
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundA phantom assembly that simulates the respiratory motion of the heart was used to investigate artifacts and their impact on defect detection.
methodsSPECT/CT images were acquired for phantoms with and without small and large cardiac defects during normal and deep breathing, and also at four static respiratory phases. Acquisitions were reconstructed with and without AC, and with misalignment of transmission and emission scans. A quantitative analysis was performed to assess artifacts. Two physicians reported on defect presence or absence and their results were evaluated.
resultsAll large defects were correctly reported. Attenuation reduced uptake in the basal LV walls, increasing FN physicians' reports for small defects. Respiratory motion reduced uptake mainly in the anterior and inferior walls increasing FP and FN reports on images without and with small defects, respectively. Artifacts due to misalignment between CT and SPECT scans in normal breathing phantoms did not influence the physicians' reports.
conclusionsAttenuation and respiratory motion correction should be applied to reduce artifacts before reporting on small defects in deep breathing conditions. Artifacts due to misalignment between CT and SPECT scans do not affect defect detection in normal breathing when the LV is co-registered in SPECT and CT images prior to AC.