Evidence map›Paper›PMID 26846123›Full record

ArticlePediatric cardiology2016

Dual-Axis Rotational Angiography is Safe and Feasible to Detect Coronary Allograft Vasculopathy in Pediatric Heart Transplant Patients: A Single-Center Experience.

Rodrigo Rios, Rohit S Loomba, Susan R Foerster, Andrew N Pelech, Todd M Gudausky

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric cardiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Rodrigo RiosDivision of Cardiology, Medical College of Wisconsin, Children's Hospital of Wisconsin, 9000 Wisconsin Avenue, Milwaukee, WI, 53226, USA. rrios@chw.org.
Rohit S LoombaDivision of Cardiology, Medical College of Wisconsin, Children's Hospital of Wisconsin, 9000 Wisconsin Avenue, Milwaukee, WI, 53226, USA.
Susan R FoersterDivision of Cardiology, Medical College of Wisconsin, Children's Hospital of Wisconsin, 9000 Wisconsin Avenue, Milwaukee, WI, 53226, USA.
Andrew N PelechDivision of Pediatric Cardiology, University of California, Davis, Sacramento, CA, USA.
Todd M GudauskyDivision of Cardiology, Medical College of Wisconsin, Children's Hospital of Wisconsin, 9000 Wisconsin Avenue, Milwaukee, WI, 53226, USA.
Children's Hospital of Wisconsin · USMedical College of Wisconsin · USUniversity of California, Davis · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Coronary allograft vasculopathy (CAV) is the leading cause of graft failure in pediatric heart transplant recipients, also adding to mortality in this patient population. Coronary angiography is routinely performed to screen for CAV, with conventional single-plane or bi-plane angiography being utilized. Dual-axis rotational coronary angiography (RA) has been described, mostly in the adult population, and may offer reduction in radiation dose and contrast volume. Experience with this in the pediatric population is limited. This study describes a single-institution experience with RA for screening for CAV in pediatric patients. The catheterization database at our institution was used to identify pediatric heart transplant recipients having undergone RA to screen for CAV. Procedural data including radiation dose, fluoroscopy time, contrast volume, and procedure time were collected for each catheterization. The number of instances in which RA was not successful, ECG changes were present, and CAV was detected were also collected for each catheterization. A total of 97 patients underwent 345 catheterizations utilizing RA. Median radiation dose-area product per kilogram was found to be 341.7 (mGy cm(2)/kg), total air kerma was 126.8 (mGy), procedure time was 69 min, fluoroscopy time was 9.9 min, and contrast volume was 13 ml. A total of 17 (2 %) coronary artery injections out of 690 could not be successfully imaged using RA. A total of 14 patients had CAV noted at any point, 10 of whom had progressive CAV. Electrocardiographic changes were documented in a total of 10 (3 %) RA catheterizations. Procedural characteristics did not differ between serial catheterizations. RA is safe and feasible for CAV screening in pediatric heart transplant recipients while offering coronary imaging in multiple planes compared to conventional angiography.

Indexed as

Cardiac CatheterizationHeart TransplantationAdolescentAdultChildChild, PreschoolCoronary AngiographyCoronary Artery DiseaseCoronary VesselsFemaleFluoroscopyGraft RejectionHumansInfantInfant, NewbornMaleAngiographyCoronaryRejectionSwingTransplantation

Identifiers

PMID26846123
OpenAlexW2300435593

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.