Evidence map›Paper›PMID 26843254›Full record

ArticleMedical physics2016

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography.

Eric Berg, Emilie Roncali, Maciej Kapusta, Junwei Du, Simon R Cherry

Abstract read
In one paragraph

Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed.

  1. Article
  2. Article
  3. A Time-Walk and Timing-Shift Correction Method for Dual-Ended Readout TOF-DOI PET Detectors.IEEE transactions on radiation and plasma medical sciences · 2025
    Article
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
  9. Performance of Dual-Ended Readout PET Detectors Based on BGO Arrays and BaSOIEEE transactions on radiation and plasma medical sciences · 2022
    Article
  10. Multiplexed imaging in oncology.Nature biomedical engineering · 2022
    Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Development and Evaluation of mini-EXPLORER: A Long Axial Field-of-View PET Scanner for Nonhuman Primate Imaging.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2018
    Article
  19. Feasibility of Using Crystal Geometry for a DOI Scintillation Detector.IEEE transactions on radiation and plasma medical sciences · 2018
    Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Eric BergDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, California 95616.
Emilie RoncaliDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, California 95616.
Maciej KapustaMolecular Imaging, Siemens Healthcare, Knoxville, Tennessee 37932.
Junwei DuDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, California 95616.
Simon R CherryDepartment of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, California 95616.

Funding

National Institute on Aging (NIA) ColonyP51OD011107 · OD · UNIVERSITY OF CALIFORNIA AT DAVIS · PI Simon J. Atkinson · 2012 to 2026
$191.5M
Enabling technologies for ultra-high sensitivity PET scanners (PQ13)R01CA170874 · NCI · UNIVERSITY OF CALIFORNIA AT DAVIS · PI BADAWI, RAMSEY D. · 2012 to 2014
$1.5M
NCI NIH HHS R01 CA170874NIH HHS P51 OD011107
6 · The paper itself

Abstract

purposeIn support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities.

methodsThis work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes.

resultsPulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3-3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%-7% with phosphor-coated crystals compared to uncoated crystals.

conclusionsThese results demonstrate the feasibility of obtaining TOF-DOI capabilities with simple block detector readout using phosphor-coated crystals.

Indexed as

Cost-Benefit AnalysisPositron-Emission TomographySignal-To-Noise RatioTime FactorsWhole Body Imaging

Identifiers

PMID26843254
PMCPMC4733082

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.