ArticleRadiology2016
Abdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience.
Article in Radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 102 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
102 citing papers in PubMed.
- AI for Opportunistic Identification of BMD and Bone Microarchitecture: A Narrative Review.Calcified tissue international · 2026Review
- Fusion of photon-counting CT and MRI improves assessment of the knee: a pilot study.Osteoarthritis imaging · 2026Article
- Potential of quantitative X-ray imaging from photon-counting CT: A novel analysis based on effective atomic number and physical density.Journal of applied clinical medical physics · 2026Article
- Photon-counting detector computed tomography in thoracic oncology: revolutionizing tumor imaging through precision and detail.Diagnostic and interventional radiology (Ankara, Turkey) · 2026Review
- Photon-counting detector CT in cardiovascular imaging: technical advances, clinical applications, and future perspectives.The international journal of cardiovascular imaging · 2026Review
- Coronary Plaque Vulnerability and Pericoronary Adipose Tissue Inflammation: Emerging Insights from Advanced CT Imaging.Medicina (Kaunas, Lithuania) · 2026Review
- Intraindividual comparison of photon-counting detector CT and third-generation dual-source energy-integrating detector CT in multiphasic contrast-enhanced abdominal CT.Scientific reports · 2026Article
- A Novel Spiral Si Drift Detector with a Constant Cathode Gap and Arbitrary Cathode Pitch Profiles.Micromachines · 2026Article
- DREAMER: Rapid and Simultaneous Multiple Contrast Magnetic Resonance Imaging of Solid and Soft Tissue.Magnetic resonance in medicine · 2026Article
- Impact of contrast medium volume on myocardial extracellular volume measurement accuracy in first-generation photon-counting detector CT.The international journal of cardiovascular imaging · 2026Article
- Applicability of Effective Atomic Number (Zeff) Image Analysis of Coronary Plaques Measured With Photon- Counting Computed Tomography.Investigative radiology · 2025Article
- A Novel Polysilicon-Fill-Strengthened Etch-Through 3D Trench Electrode Detector: Fabrication Methods and Electrical Property Simulations.Micromachines · 2025Article
- Influence of phantom design on evaluation metrics in photon counting spectral head CT: a simulation study.Journal of medical imaging (Bellingham, Wash.) · 2025Article
- Optimizing Imaging Parameters for Assessment of Hepatocellular Carcinoma Using Photon-Counting Detector Computed Tomography-Impact of Reconstruction Kernel and Slice Thickness.Tomography (Ann Arbor, Mich.) · 2025Article
- Review
- Cranial and spinal computed tomography (CT) angiography with photon-counting detector CT: comparison with angiographic and operative findings.Japanese journal of radiology · 2025Review
- Impact of patient habitus and acquisition protocol on iodine quantification in dual-source photon-counting computed tomography.Journal of medical imaging (Bellingham, Wash.) · 2024Article
- Deep silicon photon-counting CT: A first simulation-based study for assessing perceptual benefits across diverse anatomies.European journal of radiology · 2024Article
- Photon-counting computed tomography in radiology.Polish journal of radiology · 2024Review
- Milestones in CT: Past, Present, and Future.Radiology · 2023Review
42 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeTo evaluate the performance of a prototype photon-counting detector (PCD) computed tomography (CT) system for abdominal CT in humans and to compare the results with a conventional energy-integrating detector (EID). MATERIALS AND
methodsThe study was HIPAA-compliant and institutional review board-approved with informed consent. Fifteen asymptomatic volunteers (seven men; mean age, 58.2 years ± 9.8 [standard deviation]) were prospectively enrolled between September 2 and November 13, 2015. Radiation dose-matched delayed contrast agent-enhanced spiral and axial abdominal EID and PCD scans were acquired. Spiral images were scored for image quality (Wilcoxon signed-rank test) in five regions of interest by three radiologists blinded to the detector system, and the axial scans were used to assess Hounsfield unit accuracy in seven regions of interest (paired t test). Intraclass correlation coefficient (ICC) was used to assess reproducibility. PCD images were also used to calculate iodine concentration maps. Spatial resolution, noise-power spectrum, and Hounsfield unit accuracy of the systems were estimated by using a CT phantom.
resultsIn both systems, scores were similar for image quality (median score, 4; P = .19), noise (median score, 3; P = .30), and artifact (median score, 1; P = .17), with good interrater agreement (image quality, noise, and artifact ICC: 0.84, 0.88, and 0.74, respectively). Hounsfield unit values, spatial resolution, and noise-power spectrum were also similar with the exception of mean Hounsfield unit value in the spinal canal, which was lower in the PCD than the EID images because of beam hardening (20 HU vs 36.5 HU; P < .001). Contrast-to-noise ratio of enhanced kidney tissue was improved with PCD iodine mapping compared with EID (5.2 ± 1.3 vs 4.0 ± 1.3; P < .001).
conclusionThe performance of PCD showed no statistically significant difference compared with EID when the abdomen was evaluated in a conventional scan mode. PCD provides spectral information, which may be used for material decomposition.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.