Evidence map›Paper›PMID 26839592›Full record

ArticlePatient safety in surgery2016

Balloon-guided inflation osteoplasty in the treatment of Hill-Sachs lesions of the humeral head: case report of a new technique.

Gunther H Sandmann, Sebastian Siebenlist, Florian B Imhoff, Philipp Ahrens, Markus Neumaier, Thomas Freude, Peter Biberthaler

Open access · goldAbstract readCase Reports
In one paragraph

Article in Patient safety in surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Gunther H SandmannDepartment of Traumatology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, D-81675 Munich, Germany ; Department of Traumatology, Eberhard-Karls-Universitaet, Schnarrenbergstr. 9, D-72076 Tuebingen, Germany.
Sebastian SiebenlistDepartment of Traumatology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, D-81675 Munich, Germany ; Department of Orthopaedic Sports Medicine, Technical University Munich, Ismaninger Str. 22, D- 81675 Munich, Germany.
Florian B ImhoffDepartment of Traumatology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, D-81675 Munich, Germany ; Department of Orthopaedic Surgery, Krankenhaus Barmherzige Brueder, Romanstr. 93, D-80639 Munich, Germany.
Philipp AhrensDepartment of Traumatology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, D-81675 Munich, Germany ; Department of Orthopaedic Surgery, Klinikum Mittelbaden, Lilienmattstr. 5, D-76530 Baden-Baden, Germany.
Markus NeumaierDepartment of Traumatology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, D-81675 Munich, Germany.
Thomas FreudeDepartment of Traumatology, Eberhard-Karls-Universitaet, Schnarrenbergstr. 9, D-72076 Tuebingen, Germany.
Peter BiberthalerDepartment of Traumatology, Klinikum rechts der Isar, Technical University Munich, Ismaninger Str. 22, D-81675 Munich, Germany.
Klinikum rechts der Isar · DEBG Klinik Tübingen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe use of the extra-vertebral balloon osteoplasty is increasing and in the meanwhile it has become a safe surgical technique in the treatment of tibial head, distal radius and calcaneus fractures. In addition, we already could show in a biomechanical setup that the balloon osteoplasty might be a safe tool for reduction in the treatment of Hill-Sachs lesions, but clinical application has not been performed so far. CASE PRESENTATION: We report the case of a 53 year- old male patient who was referred to our Trauma department (level I trauma center) after the first manifestation of a posterior shoulder dislocation due to an epileptic seizure, originated in a- up to this date unknown -glioblastoma. After closed reduction of the dislocated shoulder the X-ray showed a subcapital fracture of the proximal humerus with a large reversed Hill-Sachs lesion. We performed an open surgery via a deltoideopectoral approach and balloon osteoplasty was used to reduce the impression fracture (Hill-Sachs lesion) before fixing the fracture with a locking plate. In the post-operative CT scan we could show an anatomical reduction of the Hill-Sachs lesion. At the follow-up examination one year after surgery the patient reached full range of motion and stated no re-dislocation of the shoulder nor instability or pain.

conclusionThe reduction of an impressed humeral head fracture by use of balloon osteoplasty is a safe technique. This technique could be a new option in the treatment of Hill-Sachs lesions and might be an alternative to well known standard procedures like the remplissage or tendon transfers without affecting rotation.

Indexed as

Balloon osteoplastyHill-Sachs lesionShoulder dislocation

Identifiers

PMID26839592
PMCPMC4736246
OpenAlexW2274051425

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.