ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2016
A new dynamic six degrees of freedom disc-loading simulator allows to provoke disc damage and herniation.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 31 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
31 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Lumbar disc herniation modelling: a review of ex-vivo mechanical models and a comparison with clinical data.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025Pooled it
- Development and evaluation of a multi-axis loading simulator for the spine, pelvis, and lumbosacral region.Scientific reports · 2026Article
- Combined Flexion, Torsion and Compression Drive Distinct Intervertebral Disc Failure Mechanisms Under Asymmetric, High-Cycle Loading.JOR spine · 2026Article
- Chondroitinase Versus Papain Digestion Leads to Different Outcome for In Vitro Simulation of Degenerated Discs.JOR spine · 2026Article
- Importance of a Systematic Intervertebral Motion Parametrization for in vivo Assessment of Spine Biomechanics.Annals of biomedical engineering · 2026Article
- Can cervical disc herniations be provokedFrontiers in bioengineering and biotechnology · 2026Article
- The Biomechanical Landscape of Lumbar Disc Herniation: Mechanobiological Insights Into Injury and Regeneration.Neurospine · 2026Review
- Article
- Exploring Mechanotransduction and Inflammation in Human Cartilaginous Endplate Cells in Blended Collagen-Agarose Hydrogels Under Cyclic Compression.Gels (Basel, Switzerland) · 2025Article
- A Comparison of Five Animal Models for Acute Intervertebral Disc Herniation Research.JOR spine · 2025Article
- Multiaxial rotational loading compromises the transition zone of the intervertebral disc: Ex vivo study using next-generation bioreactors.Bioengineering & translational medicine · 2025Article
- Spinal Cord Image Denoising Using Dncnn Algorithm.Current medical imaging · 2025Article
- A novel spine tester TO GO.JOR spine · 2024Article
- Papain Injection Creates a Nucleotomy-like Cavity for Testing Gels in Intervertebral Discs.Gels (Basel, Switzerland) · 2024Article
- Understanding the etiopathogenesis of lumbar intervertebral disc herniation: From clinical evidence to basic scientific research.JOR spine · 2024Review
- Article
- Cartilaginous endplates: A comprehensive review on a neglected structure in intervertebral disc research.JOR spine · 2023Review
- Off-Axis Loading Fixture for Spine Biomechanics: Combined Compression and Bending.Journal of biomechanical engineering · 2023Article
- Toward the Next Generation of Spine Bioreactors: Validation of an Ex Vivo Intervertebral Disc Organ Model and Customized Specimen Holder for Multiaxial Loading.ACS biomaterials science & engineering · 2022Article
- Cervical spine and muscle adaptation after spaceflight and relationship to herniation risk: protocol from 'Cervical in Space' trial.BMC musculoskeletal disorders · 2022Article
Corrections and comments
- Erratum issued
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe cause of disc herniation is not well understood yet. It is assumed that heavy lifting and extreme postures can cause small injuries starting either in the inner anulus or from the outside close to the endplate. Such injuries are accumulated over years until its structure is weakened and finally a single loading event leads to a sudden failure of the last few intact lamellae. This paper describes a novel, custom-developed dynamic 6-DOF disc-loading simulator that allows complex loading to provoke such disc damage and herniations.
methodsThe machine's axes are driven by six independent servomotors providing high loads (10 kN axial compression, 2 kN shear, 100 Nm torque) up to 5 Hz. A positional accuracy test was conducted to validate the machine. Subsequently, initial experiments with lumbar ovine motion segments under complex loading were performed. After testing, the discs were examined in an ultra-high field MRI (11.7 T). A three-dimensional reconstruction was performed to visualise the internal disc lesions.
resultsValidation tests demonstrated positioning with an accuracy of ≤0.08°/≤0.026 mm at 0.5 Hz and ≤0.27°/≤0.048 mm at 3.0 Hz with amplitudes of ±17°/±2 mm. Typical failure patterns and herniations could be provoked with complex asymmetrical loading protocols. Loading with axial compression, flexion, lateral bending and torsion lead in 8 specimens to 4 herniated discs, two protrusions and two delaminations. All disc failures occurred in the posterior region of the disc.
conclusionThis new dynamic disc-loading simulator has proven to be able to apply complex motion combinations and allows to create artificial lesions in the disc with complex loading protocols. The aim of further tests is to better understand the mechanisms by which disc failure occurs at the microstructural level under different loading conditions. Visualisation with ultra-high field MRI at different time points is a promising method to investigate the gradual development of such lesions, which may finally lead to disc failure. These kinds of experiments will help to better investigate the mechanical failure of discs to provide new insights into the initiation of intervertebral disc herniation. This device will also serve for many other applications in spine biomechanics research.
Indexed as
Identifiers
26838335What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.