ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2016
Anatomical feasibility for safe occipital condyle screw fixation.
Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 11 citations in OpenAlex.
- Safety and Efficacy of Intraoperative Doppler Sonography-Assisted Cervical Pedicle Screw Fixation-A Retrospective Comparison with Conventional Pedicle Screw Implantation.Global spine journal · 2023Article
- Article
- Diagnostic Technology for Spine Pathology.Asian spine journal · 2022Article
- Computed Tomographic Study of Occipital Thickness in Ethnic Malays.Malaysian orthopaedic journal · 2022Article
- Occipital condyle screw fixation after posterior decompression for Chiari malformation: Technical report and application.Surgical neurology international · 2021Article
- Morphometric Evaluation of Occipital Condyles: Defining Optimal Trajectories and Safe Screw Lengths for Occipital Condyle-Based Occipitocervical Fixation in Indian Population.Asian spine journal · 2018Article
- Quantitative analysis of unusual entrance of the vertebral artery into the cervical foramen (V2 segment) and its clinical implications.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe occipital condyle (OC) screw can be a viable alternative option for the occipito-cervical fixation. However, the risk of vertebral artery (VA) injury during the direct OC screw fixation has not been adequately assessed. The purpose of this study was to establish the course of the VA (V3) relative to the nearby osseous structures to estimate the feasibility of OC screw fixation and describe its anatomical relationship depending on patient's age and sex.
methodsA total of 387 three-dimensional computed tomographic angiograms (3D-CTA) were used and compared between two age groups. The vertebral artery diameter and two kinds of bony space were measured. The occipito-C1 arch space (O-C1S) and VA-occipital bone distance (VOD, six entry points) were measured on both sides. The feasibility of direct OC screw fixation can be represented by the VOD value; the minimum feasible value was determined to be 4 mm. Angular measurements (O-C1A and O-C2A) were also taken to assess their relationship to the bony space.
resultsThe mean value of the O-C1S ranged from 9.0 to 9.9 mm. The mean value of the VOD ranged from 3.2 to 3.5 mm, and the proportion of individuals for which direct OC screw fixation was considered feasible ranged from 32 to 42 % in both age groups and there was no significant difference between two age groups. The VOD value was not affected by laterality or by gender (P > 0.05). The mean kyphosis of the O-C1A (-5° ± 5.2°, range -22° to 8°) was significantly smaller in the young age group compared to the older age group (-7.6° ± 5.3°, range -26° to 2°). The mean lordosis of the O-C2A (12.4° ± 6.4°, range 3°-33°) was significantly higher in the young age group compared to the older age group (10.4° ± 6.4°, range 0°-36°).
conclusionsThe direct OC screw fixation was not possible in a considerable number of cases due to the limited space and the position of the VA regardless of age group. Only about one quarter (21-24 %) of all patients was affordable to place the direct OC screw bilaterally. There was more space available to place the direct OC screw when the angle of the upper cervical spine is more kyphotic.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.