SynthesisThe Cochrane database of systematic reviews2016
Retention procedures for stabilising tooth position after treatment with orthodontic braces.
Synthesis in The Cochrane database of systematic reviews, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 51 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Vacuum-formed Retainer Versus Bonded Retainer to Prevent Relapse After Orthodontic Treatment - A Randomized Controlled Trial About Stability and Patients' Perceptions
A Randomised Crossover Clinical Trial to Compare the Effects of Different Storage Conditions on Removable Retainers
Who cites it
51 citing papers in PubMed, 3 syntheses or guidelines pooled it, 365 citations in OpenAlex.
- Wisdom teeth removal and anterior alignment stability after orthodontic treatment-a systematic review.Clinical oral investigations · 2026Pooled it
- Impact of bonding protocols and physical-mechanical properties of composite on durability and failure rate of fixed orthodontic retainers: a systematic review of laboratory studies.BMC oral health · 2025Pooled it
- The effects of fixed and removable orthodontic retainers: a systematic review.Progress in orthodontics · 2016Pooled it
- Transfer accuracy of three different virtually designed CAD/CAM retainers - baseline results of a randomized clinical trial.Clinical oral investigations · 2026Trial
- Effectiveness of CAD/CAM titanium fixed lingual retainer versus conventional stainless steel fixed retainer (randomized controlled clinical trial).Clinical oral investigations · 2025Trial
- Influence of fixed orthodontic steel retainers on gingival health and recessions of mandibular anterior teeth in an intact periodontium - a randomized, clinical controlled trial.BMC oral health · 2024Trial
- Periodontal indexes of two types of 3 x 3 retainers: 0.032-in SS V-loop versus 0.0215-in SS coaxial - a randomized crossover trial.Dental press journal of orthodontics · 2024Trial
- Comparison of speech changes caused by four different orthodontic retainers: a crossover randomized clinical trial.Dental press journal of orthodontics · 2024Trial
- Comparison between round multi-strand wire and rectangular wire bonded retainers: a randomized clinical trial.Dental press journal of orthodontics · 2023Trial
- Evaluation of effectiveness and stability of aligner treatments using the Peer Assessment Rating Index.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2021Trial
- Prevalence of occlusal deviations and orthodontic treatment in the Northern Finland Birth Cohort of 1986.Acta odontologica Scandinavica · 2026Article
- Cone-beam CT evaluation of impacted mandibular third molars and their possible association with mandibular incisor crowding.Medicina oral, patologia oral y cirugia bucal · 2026Article
- Effect of psidium guajava fruit suspension on periodontium following orthodontic tooth movement in wistar rats-histologic findings.The Saudi dental journal · 2026Article
- Influence of early myofunctional training on maxillary arch development in children aged 4-7 years with mild oral habits: a controlled pilot study.Frontiers in pediatrics · 2026Article
- Comparison of Mechanical, Surface, and Chemical Properties of Different Thermoplastic Retainer Materials before and after Thermoforming: Scanning Electron Microscopy and Fourier Transform Infrared Spectroscopy Analyses.Turkish journal of orthodontics · 2025Article
- Effects of cleaning protocols on surface roughness and optical properties of thermoplastic orthodontic retainers.Clinical oral investigations · 2025Article
- Calcium phosphate nanoclusters modify periodontium remodeling and minimize orthodontic relapse.Biomaterials · 2025Article
- Impact of simulated gastric acid on the physical and mechanical properties of vacuum-formed retainers: an in vitro study.BMC oral health · 2025Article
- Comparing the Impact of Titanium and Stainless Steel Retainers on Lower Incisor Stability, Periodontal Health, and Retainer Survival: A Preliminary Study.Turkish journal of orthodontics · 2024Article
- Mesenchymal stem cell-derived exosomes: a potential cell-free therapy for orthodontic tooth stability management.Stem cell research & therapy · 2024Review
Corrections and comments
- Commented on by
- Updated by
- Update of
Authors and funding
5 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundRetention is the phase of orthodontic treatment that attempts to keep teeth in the corrected positions after treatment with orthodontic braces. Without a phase of retention, there is a tendency for teeth to return to their initial position (relapse). To prevent relapse, almost every person who has orthodontic treatment will require some type of retention.
objectivesTo evaluate the effects of different retention strategies used to stabilise tooth position after orthodontic braces. SEARCH
methodsWe searched the following databases: the Cochrane Oral Health Group's Trials Register (to 26 January 2016), the Cochrane Central Register of Controlled Trials (CENTRAL) (2015, Issue 12), MEDLINE via Ovid (1946 to 26 January 2016) and EMBASE via Ovid (1980 to 26 January 2016). We searched for ongoing trials in the US National Institutes of Health Trials Register (ClinicalTrials.gov) and the World Health Organization (WHO) International Clinical Trials Registry Platform. We applied no language or date restrictions in the searches of the electronic databases. We contacted authors of randomised controlled trials (RCTs) to help identify any unpublished trials. SELECTION CRITERIA: RCTs involving children and adults who had had retainers fitted or adjunctive procedures undertaken to prevent relapse following orthodontic treatment with braces. DATA COLLECTION AND ANALYSIS: Two review authors independently screened eligible studies, assessed the risk of bias in the trials and extracted data. The outcomes of interest were: how well the teeth were stabilised, failure of retainers, adverse effects on oral health and participant satisfaction. We calculated mean differences (MD) with 95% confidence intervals (CI) for continuous data and risk ratios (RR) with 95% CI for dichotomous outcomes. We conducted meta-analyses when studies with similar methodology reported the same outcome. We prioritised reporting of Little's Irregularity Index to measure relapse. MAIN
resultsWe included 15 studies (1722 participants) in the review. There are also four ongoing studies and four studies await classification. The 15 included studies evaluated four comparisons: removable retainers versus fixed retainers (three studies); different types of fixed retainers (four studies); different types of removable retainers (eight studies); and one study compared a combination of upper thermoplastic and lower bonded versus upper thermoplastic with lower adjunctive procedures versus positioner. Four studies had a low risk of bias, four studies had an unclear risk of bias and seven studies had a high risk of bias. Removable versus fixed retainers Thermoplastic removable retainers provided slightly poorer stability in the lower arch than multistrand fixed retainers: MD (Little's Irregularity Index, 0 mm is stable) 0.6 mm (95% CI 0.17 to 1.03). This was based on one trial with 84 participants that was at high risk of bias; it was low quality evidence. Results on retainer failure were inconsistent. There was evidence of less gingival bleeding with removable retainers: RR 0.53 (95% CI 0.31 to 0.88; one trial, 84 participants, high risk of bias, low quality evidence), but participants found fixed retainers more acceptable to wear, with a mean difference on a visual analogue scale (VAS; 0 to 100; 100 being very satisfied) of -12.84 (95% CI -7.09 to -18.60). Fixed versus fixed retainersThe studies did not report stability, adverse effects or participant satisfaction. It was possible to pool the data on retention failure from three trials that compared polyethylene ribbon bonded retainer versus multistrand retainer in the lower arch with an RR of 1.10 (95% CI 0.77 to 1.57; moderate heterogeneity; three trials, 228 participants, low quality evidence). There was no evidence of a difference in failure rates. It was also possible to pool the data from two trials that compared the same types of upper fixed retainers, with a similar finding: RR 1.25 (95% CI 0.87 to 1.78; low heterogeneity; two trials, 174 participants, low quality evidence). Removable versus removable retainersOne study at low risk of bias comparing upper and lower part-time thermoplastic versus full-time thermoplastic retainer showed no evidence of a difference in relapse (graded moderate quality evidence). Another study, comparing part-time and full-time wear of lower Hawley retainers, found no evidence of any difference in relapse (low quality evidence). Two studies at high risk of bias suggested that stability was better in the lower arch for thermoplastic retainers versus Hawley, and for thermoplastic full-time versus Begg (full-time) (both low quality evidence).In one study, participants wearing Hawley retainers reported more embarrassment more often than participants wearing thermoplastic retainers: RR 2.42 (95% CI 1.30 to 4.49; one trial, 348 participants, high risk of bias, low quality evidence). They also found Hawley retainers harder to wear. There was conflicting evidence about survival rates of Hawley and thermoplastic retainers. Other retainer comparisonsAnother study with a low risk of bias looked at three different approaches to retention for people with crowding, but normal jaw relationships. The study found that there was no evidence of a difference in relapse between the combination of an upper thermoplastic and lower canine to canine bonded retainer and the combination of an upper thermoplastic retainer and lower interproximal stripping, without a lower retainer. Both these approaches are better than using a positioner as a retainer. AUTHORS'
conclusionsWe did not find any evidence that wearing thermoplastic retainers full-time provides greater stability than wearing them part-time, but this was assessed in only a small number of participants.Overall, there is insufficient high quality evidence to make recommendations on retention procedures for stabilising tooth position after treatment with orthodontic braces. Further high quality RCTs are needed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.