ArticleJournal of neural engineering2016
Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates.
Article in Journal of neural engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 75 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
75 citing papers in PubMed, 1 synthesis or guideline pooled it, 161 citations in OpenAlex.
- Foreign Body Reaction to Implanted Biomaterials and Its Impact in Nerve Neuroprosthetics.Frontiers in bioengineering and biotechnology · 2021Pooled it
- Multifunctional material platforms for neural interfaces: active orchestration of dynamic foreign body response across implantation lifetimes.Bioactive materials · 2026Review
- Article
- Electronics with switchable flexibility for 3D conforming neural interfaces.Science advances · 2026Article
- Electrochemical characterization and chronic stability of Utah electrode arrays for intracortical microstimulation.Frontiers in neuroscience · 2026Article
- Immune-compatible designs of semiconducting polymers for bioelectronics with suppressed foreign-body response.Nature materials · 2026Article
- Electrical characterization and accelerated aging of amorphous silicon carbide implantable encapsulation.Journal of neural engineering · 2025Article
- Silicon Carbide Neural Interfaces: A Review of Progress Toward Monolithic Devices.Nanomaterials (Basel, Switzerland) · 2025Review
- UV Laser-Induced Carbon Microelectrode Arrays for Neuronal Recordings.Advanced healthcare materials · 2025Article
- Long-term performance of intracortical microelectrode arrays in 14 BrainGate clinical trial participants.medRxiv : the preprint server for health sciences · 2025Article
- Biological and Mechanical Limitations for Chronic Fast-Scan Cyclic Voltammetry Sensor Design.Advanced materials technologies · 2025Article
- Quantifying physical degradation alongside recording and stimulation performance of 980 intracortical microelectrodes chronically implanted in three humans for 956-2130 days.Acta biomaterialia · 2025Article
- In vivo microelectrode arrays for neuroscience.Nature reviews. Methods primers · 2025Article
- Intravascular delivery of an ultraflexible neural electrode array for recordings of cortical spiking activity.Nature communications · 2024Article
- Quantifying physical degradation alongside recording and stimulation performance of 980 intracortical microelectrodes chronically implanted in three humans for 956-2246 days.medRxiv : the preprint server for health sciences · 2024Article
- NeuroRoots, a bio-inspired, seamless brain machine interface for long-term recording in delicate brain regions.AIP advances · 2024Article
- Planar amorphous silicon carbide microelectrode arrays for chronic recording in rat motor cortex.Biomaterials · 2024Article
- Bioelectronic Neural Interfaces: Improving Neuromodulation Through Organic Conductive Coatings.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Ultraflexible electrodes for recording neural activity in the mouse spinal cord during motor behavior.Cell reports · 2024Article
- Flexible circumferential bioelectronics to enable 360-degree recording and stimulation of the spinal cord.Science advances · 2024Article
15 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 3 institutions in 1 country.
Funding
Abstract
objectiveSignal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. APPROACH: We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. MAIN
resultsSEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. SIGNIFICANCE: These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does not prevent useful recordings for several years. Progressive meningeal fibrosis encapsulates and lifts MEAs out of the cortex while ongoing foreign body reactions lead to progressive degradation of the materials. Long-term impedance drops are due to the corrosion of platinum, cracking and delamination of parylene, and delamination of silicone elastomer. Oxygen radicals released by cells of the immune system likely mediate the degradation of these materials. Future MEA designs must address these problems through more durable insulation materials, more inert electrode alloys, and pharmacologic suppression of fibroblasts and leukocytes.
Indexed as