ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2017
Morphological evaluation of the sagittal plane femoral load-bearing surface in computer-simulated virtual total knee arthroplasty implantation at different flexion angles.
Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 8 citations in OpenAlex.
- High and Varied Anterior Condyle of the Distal Femur Is Associated with Limited Flexion in Varus Knee Osteoarthritis.Cartilage · 2021Article
- Flexible versus standard intramedullary rod in posterior stabilized primary total knee arthroplasty: protocol for a randomized controlled trial.Journal of orthopaedic surgery and research · 2020Article
- Flexing and downsizing the femoral component is not detrimental to patellofemoral biomechanics in posterior-referencing cruciate-retaining total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018Article
- Risk factors and outcomes in asymmetrical femoral component size for posterior referencing bilateral total knee arthroplasty: a matched pair analysis.BMC musculoskeletal disorders · 2018Article
- Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2018Article
- Differences between native and prosthetic knees in terms of cross-sectional morphology of the femoral trochlea: a study based on three-dimensional models and virtual total knee arthroplasty.BMC musculoskeletal disorders · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo examine the effect of implantation of the femoral component of a total knee arthroplasty (TKA) system in 0°, 3°, and 6° of flexion on the sagittal plane morphology of the femoral load-bearing surfaces. It was hypothesized that increasing the flexion angle would result in undersizing of the anterior surface without changing the flexion gap.
methodsComputer simulation of a TKA using three-dimensional models of 10 healthy knees, matched to three different sized femoral components. Size discrepancy in the sagittal plane anterior, distal, and posterior joint surfaces between the native and prosthetic knees was calculated at 0°, 3°, and 6° of flexion.
resultsThe required component size varied with the angle of implantation: 0°, size 3/size 4 (N = 7/3), 3°, size 3 (N = 10); and 6°, size 2/size 3 (N = 4/6). Component undersizing ranged between 4.4-6.3 mm at the anterior lateral surface, with a significant difference between 0° and 6° (p < 0.05), and 1.2-3.5 mm at the anterior medial surface. Component oversizing of the distal surface of the lateral condyle (2.9 mm) and undersizing of the medial surface of the posterior condyle (1.6-2.3 mm) were comparable at all three flexion angles of component implantation.
conclusionsIncreasing the flexion angle of implantation increased the incidence of using a smaller size of femoral component without significant interference with the flexion gap. However, the effect of a smaller femoral component on undersizing of the anterior surface of the condyle and the impact on the extensor mechanism need to be considered.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.