Evidence map›Paper›PMID 26809010›Full record

ArticlePloS one2016

Accuracy of Non-Enhanced CT in Detecting Early Ischemic Edema Using Frequency Selective Non-Linear Blending.

Georg Bier, Malte N Bongers, Hendrik Ditt, Benjamin Bender, Ulrike Ernemann, Marius Horger

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Mesenteric ischemia: what the radiologist needs to know.Cardiovascular diagnosis and therapy · 2019
    Review
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Georg BierDepartment of Diagnostic and Interventional Radiology, Eberhard Karls-University Tuebingen, D-72076, Tuebingen, Germany.
Malte N BongersDepartment of Diagnostic and Interventional Radiology, Eberhard Karls-University Tuebingen, D-72076, Tuebingen, Germany.
Hendrik DittSiemens AG Healthcare, Imaging & Therapy Systems Computed Tomography & Radiation Oncology, Siemensstr. 1, D-91301, Forchheim, Germany.
Benjamin BenderDepartment of Neuroradiology, Eberhard Karls-University Tuebingen, D-72076, Tuebingen, Germany.
Ulrike ErnemannDepartment of Neuroradiology, Eberhard Karls-University Tuebingen, D-72076, Tuebingen, Germany.
Marius HorgerDepartment of Diagnostic and Interventional Radiology, Eberhard Karls-University Tuebingen, D-72076, Tuebingen, Germany.
University of Tübingen · DESiemens Healthcare (Germany) · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIschemic brain edema is subtle and hard to detect by computed tomography within the first hours of stroke onset. We hypothesize that non-enhanced CT (NECT) post-processing with frequency-selective non-linear blending ("best contrast"/BC) increases its accuracy in detecting edema and irreversible tissue damage (infarction).

methodsWe retrospectively analyzed the NECT scans of 76 consecutive patients with ischemic stroke (exclusively middle cerebral artery territory-MCA) before and after post-processing with BC both at baseline before reperfusion therapy and at follow-up (5.73±12.74 days after stroke onset) using the Alberta Stroke Program Early CT Score (ASPECTS). We assessed the differences in ASPECTS between unprocessed and post-processed images and calculated sensitivity, specificity, and predictive values of baseline NECT using follow-up CT serving as reference standard for brain infarction.

resultsNECT detected brain tissue hypoattenuation in 35 of 76 patients (46.1%). This number increased to 71 patients (93.4%) after post-processing with BC. Follow-up NECT confirmed brain infarctions in 65 patients (85.5%; p = 0.012). Post-processing increased the sensitivity of NECT for brain infarction from 35/65 (54%) to 65/65 (100%), decreased its specificity from 11/11 (100%) to 7/11 (64%), its positive predictive value (PPV) from 35/35 (100%) to 65/69 (94%) and increased its accuracy 46/76 (61%) to 72/76 (95%).

conclusionsThis post-hoc analysis suggests that post-processing of NECT with BC may increase its sensitivity for ischemic brain damage significantly.

Indexed as

AdultAgedAged, 80 and overBrain EdemaFemaleHumansMaleMiddle AgedRetrospective StudiesStrokeTomography, X-Ray Computed

Identifiers

PMID26809010
PMCPMC4726582
OpenAlexW2261194008

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.