Evidence map›Paper›PMID 26790093›Full record

ArticlePhysical biology2016

Computational simulation of platelet interactions in the initiation of stent thrombosis due to stent malapposition.

Jennifer K W Chesnutt, Hai-Chao Han

Open access · greenAbstract read
In one paragraph

Article in Physical biology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
3.5field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 31 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Review
  12. Article
  13. Intermittent Aortic Valve Opening and Risk of Thrombosis in Ventricular Assist Device Patients.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
  14. LVAD Outflow Graft Angle and Thrombosis Risk.ASAIO journal (American Society for Artificial Internal Organs : 1992)
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Jennifer K W ChesnuttCardiovascular Biomechanics Laboratory, Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, USA.
Hai-Chao HanCardiovascular Biomechanics Laboratory, Department of Mechanical Engineering, The University of Texas at San Antonio, San Antonio, TX, USA.
The University of Texas at San Antonio · US

Funding

RCMI Center for Interdiscplinary Health Research CIHRG12MD007591 · NIMHD · UNIVERSITY OF TEXAS SAN ANTONIO · PI PERRY, GEORGE · 2012 to 2016
$10.4M
Biomechanical Mechanisms of Artery TortuosityR01HL095852 · NHLBI · UNIVERSITY OF TEXAS SAN ANTONIO · PI HAN, HAI-CHAO · 2010 to 2014
$1.8M
NHLBI NIH HHS R01 HL095852NHLBI NIH HHS R01HL095852NIMHD NIH HHS G12 MD007591NIMHD NIH HHS G12MD007591).
6 · The paper itself

Abstract

Coronary stenting is one of the most commonly used approaches to open coronary arteries blocked due to atherosclerosis. Stent malapposition can induce thrombosis but the microscopic process is poorly understood. The objective of this study was to determine the platelet-level process by which different extents of stent malapposition affect the initiation of stent thrombosis. We utilized a discrete element model to computationally simulate the transport, adhesion, and activation of thousands of individual platelets and red blood cells during thrombus initiation in stented coronary arteries. Simulated arteries contained a malapposed stent with a specified gap distance (0, 10, 25, 50, or 200 μm) between the struts and endothelium. Platelet-level details of thrombus formation near the proximal-most strut were measured during the simulations. The relationship between gap distance and amount of thrombus in the artery varied depending on different conditions (e.g., amount of dysfunctional endothelium, shear-induced activation of platelets, and thrombogenicity of the strut). Without considering shear-induced platelet activation, the largest gap distance (200 μm) produced no recirculation and less thrombus than the smallest two gap distances (0 and 10 μm) that created recirculation downstream of the strut. However, with the occurrence of shear-induced platelet activation, the largest gap distance produced more thrombus than the two smallest gap distances, but less thrombus than an intermediate gap distance (25 μm). A large gap distance was not necessarily the most thrombogenic, in contrast to implications of some computational fluid dynamics studies. The severity of stent malapposition affected initial stent thrombosis differently depending on various factors related to fluid recirculation, platelet trajectories, shear stress, and endothelial condition.

Indexed as

Computer SimulationPlatelet ActivationBlood PlateletsCoronary VesselsHumansHydrodynamicsStentsStress, MechanicalThrombosis

Identifiers

PMID26790093
PMCPMC5039126
OpenAlexW2468805276

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.