Evidence map›Paper›PMID 26780790›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2016

Quantitative Ultrasound for Monitoring High-Intensity Focused Ultrasound Treatment In Vivo.

Goutam Ghoshal, Jeremy P Kemmerer, Chandra Karunakaran, Rita J Miller, Michael L Oelze

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Overview of Therapeutic Ultrasound Applications and Safety Considerations: 2024 Update.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2025
    Review
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Goutam Ghoshal
Jeremy P Kemmerer
Chandra Karunakaran
Rita J Miller
Michael L Oelze

Funding

Use of quantitative ultrasound to stage, monitor, and assess HIFU treatmentR01EB008992 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI OELZE, MICHAEL L. · 2008 to 2012
$1.8M
NIBIB NIH HHS R01 EB008992
6 · The paper itself

Abstract

The success of any minimally invasive treatment procedure can be enhanced significantly if combined with a robust noninvasive imaging modality that can monitor therapy in real time. Quantitative ultrasound (QUS) imaging has been widely investigated for monitoring various treatment responses such as chemotherapy, radiation, and thermal therapy. Previously, we demonstrated the feasibility of using spectral-based QUS parameters to monitor high-intensity focused ultrasound (HIFU) treatment of in situ tumors in euthanized rats [Ultrasonic Imaging 36(4), 239-255, 2014]. In the present study, we examined the use of spectral-based QUS parameters to monitor HIFU treatment of in vivo rat mammary adenocarcinoma tumors (MAT) where significant tissue motion was present. HIFU was applied to tumors in rats using a single-element transducer. During the off part of the HIFU duty cycle, ultrasound backscatter was recorded from the tumors using a linear array co-aligned with the HIFU focus. A total of 10 rats were treated with HIFU in this study with an additional sham-treated rat. Spectral parameters from the backscatter coefficient, i.e., effective scatterer diameter (ESD) and effective acoustic concentration (EAC), were estimated. The changes of each parameter during treatment were compared with a temperature profile recorded by a fine-needle thermocouple inserted into the tumor a few millimeters behind the focus of the HIFU transducer. The mean ESD changed from 121 ±6 to [Formula: see text], and the EAC changed from 33 ±2 to [Formula: see text] during HIFU exposure as the temperature increased on average from 38.7 ±1.0 (°)C to 64.2 ±2.7 (°)C. The changes in ESD and EAC were linearly correlated with the changes in tissue temperature during the treatment. When HIFU was turned off, the ESD increased from 81 ±8 to [Formula: see text] and the EAC dropped from 46 ±3 to 36±2 dB/cm(3) as the temperature decreased from 64.2 ±2.7 (°)C to 45 ±2.7 (°)C. QUS was demonstrated in vivo to track temperature elevations caused by HIFU exposure.

Indexed as

High-Intensity Focused Ultrasound AblationTransducersUltrasonographyAcousticsAdenocarcinomaAnimalsBreast NeoplasmsFemaleNeoplasms, ExperimentalRatsRats, Inbred F344

Identifiers

PMID26780790
PMCPMC5551400

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.