ArticleInternational orthopaedics2016
A forty millimetre head significantly improves range of motion compared with a twenty eight millimetre head in total hip arthroplasty using a computed tomography-based navigation system.
Article in International orthopaedics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 19 citations in OpenAlex.
- Accuracy of Cup Alignment in Total Hip Arthroplasty: A Comparison Between Portable Navigation and Goniometer.Cureus · 2024Article
- Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study.Journal of orthopaedic surgery and research · 2022Article
- Personalized Hip Joint Replacement with Large Diameter Head: Current Concepts.Journal of clinical medicine · 2022Review
- Global diversity in bearings in primary THA.EFORT open reviews · 2020Review
- Is there a reduction in risk of revision when 36-mm heads instead of 32 mm are used in total hip arthroplasty for patients with proximal femur fractures?Acta orthopaedica · 2020Article
- An accelerometer-based navigation system provides acetabular cup orientation accuracy comparable to that of computed tomography-based navigation during total hip arthroplasty in the supine position.Journal of orthopaedic surgery and research · 2020Article
- Clinical accuracy and precision of hip resurfacing arthroplasty using computed tomography-based navigation.International orthopaedics · 2019Article
- Head size in primary total hip arthroplasty.EFORT open reviews · 2018Article
- Current standard rules of combined anteversion prevent prosthetic impingement but ignore osseous contact in total hip arthroplasty.International orthopaedics · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeLarger-diameter (≥40 mm) femoral heads decrease the incidence of post-operative dislocation in total hip arthroplasty (THA). This study was conducted to discover whether larger-diameter femoral heads result in greater range of motion of the hip with the use of a computed tomography (CT)-based navigation system.
methodsThirty-nine primary THAs were performed via a posterolateral approach using a CT-based navigation system. The stem was inserted in the femur in line with the original femoral neck anteversion. Considering the range of motion during various daily activities which could occur without impingement, the cup anteversion was decided at 10 ° increments according to the stem anteversion. While the cup inclination was set at 40 ° in order to avoid a high inclination angle to prevent the edge roading between the HXLPE liner and ceramic head. After implantation, trial liners and femoral heads were used with either 28 or 40 mm diameter. Maximal hip flexion, extension, abduction, external rotation in extension at 0° and internal rotation angles in flexion at 90 ° were measured. The differences between the ranges of motion with the 40-mm and 28-mm heads were tested. The results were assessed with paired Student t-tests.
resultsThe ranges of motion in flexion, extension, abduction and internal rotation angles improved significantly with the 40-mm heads compared with the 28-mm heads. The ranges of motion of cases where maximal flexion angle was 90° or less were excluded, improved significantly with the 40 mm heads.
conclusionsWe concluded that the larger-diameter 40-mm femoral prosthetic heads result in greater ranges of motion in flexion, extension, abduction and internal rotation.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.