ArticleMagnetic resonance in medicine2017
A fast and flexible MRI system for the study of dynamic vocal tract shaping.
Article in Magnetic resonance in medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed, 60 citations in OpenAlex.
- Online Spatiotemporally Constrained Reconstruction for Real-Time Interactive MRI.Magnetic resonance in medicine · 2026Article
- Vertical larynx actions and intergestural timing stability in Hausa ejectives and implosives.Phonetica · 2024Article
- Real-time speech MRI datasets with corresponding articulator ground-truth segmentations.Scientific data · 2023Article
- Automatic Multiple Articulator Segmentation in Dynamic Speech MRI Using a Protocol Adaptive Stacked Transfer Learning U-NET Model.Bioengineering (Basel, Switzerland) · 2023Article
- Speech disorders in patients with Tongue squamous cell carcinoma: A longitudinal observational study based on a questionnaire and acoustic analysis.BMC oral health · 2023Observational
- Real-Time Magnetic Resonance Imaging.Journal of magnetic resonance imaging : JMRI · 2022Review
- Aliasing artifact reduction in spiral real-time MRI.Magnetic resonance in medicine · 2021Article
- A multispeaker dataset of raw and reconstructed speech production real-time MRI video and 3D volumetric images.Scientific data · 2021Article
- Optimizing constrained reconstruction in magnetic resonance imaging for signal detection.Physics in medicine and biology · 2021Article
- Deblurring for spiral real-time MRI using convolutional neural networks.Magnetic resonance in medicine · 2020Article
- Realistic Dynamic Numerical Phantom for MRI of the Upper Vocal Tract.Journal of imaging · 2020Article
- Improved real-time tagged MRI using REALTAG.Magnetic resonance in medicine · 2020Article
- A 12-channel flexible receiver coil for accelerated tongue imaging.Magma (New York, N.Y.) · 2020Article
- A modular architecture for articulatory synthesis from gestural specification.The Journal of the Acoustical Society of America · 2019Article
- Opportunities in Interventional and Diagnostic Imaging by Using High-Performance Low-Field-Strength MRI.Radiology · 2019Article
- Intermittently tagged real-time MRI reveals internal tongue motion during speech production.Magnetic resonance in medicine · 2019Article
- Crossing muscle fibers of the human tongue resolved in vivo using constrained spherical deconvolution.Journal of magnetic resonance imaging : JMRI · 2019Article
- Task-dependence of articulator synergies.The Journal of the Acoustical Society of America · 2019Article
- 3D dynamic MRI of the vocal tract during natural speech.Magnetic resonance in medicine · 2019Article
- Reconstruction of vocal tract geometries from biomechanical simulations.International journal for numerical methods in biomedical engineering · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 2 countries.
Funding
Abstract
purposeThe aim of this work was to develop and evaluate an MRI-based system for study of dynamic vocal tract shaping during speech production, which provides high spatial and temporal resolution.
methodsThe proposed system utilizes (a) custom eight-channel upper airway coils that have high sensitivity to upper airway regions of interest, (b) two-dimensional golden angle spiral gradient echo acquisition, (c) on-the-fly view-sharing reconstruction, and (d) off-line temporal finite difference constrained reconstruction. The system also provides simultaneous noise-cancelled and temporally aligned audio. The system is evaluated in 3 healthy volunteers, and 1 tongue cancer patient, with a broad range of speech tasks.
resultsWe report spatiotemporal resolutions of 2.4 × 2.4 mm
conclusionA synergistic combination of custom coils, spiral acquisitions, and constrained reconstruction enables visualization of rapid speech with high spatiotemporal resolution in multiple planes. Magn Reson Med 77:112-125, 2017. © 2016 Wiley Periodicals, Inc.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.