Evidence map›Paper›PMID 26770492›Full record

ArticleInternational journal of clinical and experimental medicine2015

Development and evaluation of the quantitative real-time PCR assay in detection and typing of herpes simplex virus in swab specimens from patients with genital herpes.

Junlian Liu, Yong Yi, Wei Chen, Shaoyan Si, Mengmeng Yin, Hua Jin, Jianjun Liu, Jinlian Zhou, Jianzhong Zhang

Open access · greenAbstract read
In one paragraph

Article in International journal of clinical and experimental medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.4field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Evaluation of RealStar®BioMed research international · 2019
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Junlian LiuDepartment of Dermatology, 306 Hospital of PLA Beijing 100101, P. R. China.
Yong YiDepartment of Pathology, 306 Hospital of PLA Beijing 100101, P. R. China.
Wei ChenDepartment of Dermatology, 306 Hospital of PLA Beijing 100101, P. R. China.
Shaoyan SiDepartment of Pathology, 306 Hospital of PLA Beijing 100101, P. R. China.
Mengmeng YinDepartment of Dermatology, 306 Hospital of PLA Beijing 100101, P. R. China.
Hua JinDepartment of Pathology, 306 Hospital of PLA Beijing 100101, P. R. China.
Jianjun LiuDepartment of Dermatology, 306 Hospital of PLA Beijing 100101, P. R. China.
Jinlian ZhouDepartment of Pathology, 306 Hospital of PLA Beijing 100101, P. R. China.
Jianzhong ZhangDepartment of Pathology, 306 Hospital of PLA Beijing 100101, P. R. China.
PLA 306 Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Genital herpes (GH), which is caused mainly by herpes simplex virus (HSV)-2 and HSV-1, remains a worldwide problem. Laboratory confirmation of GH is important, particularly as there are other conditions which present similarly to GH, while atypical presentations of GH also occur. Currently, virus culture is the classical method for diagnosis of GH, but it is time consuming and with low sensitivity. A major advance for diagnosis of GH is to use Real-time polymerase chain reaction (PCR). In this study, to evaluate the significance of the real-time PCR method in diagnosis and typing of genital HSV, the primers and probes targeted at HSV-1 DNA polymerase gene and HSV-2 glycoprotein D gene fraction were designed and applied to amplify DNA from HSV-1 or HSV-2 by employing the real-time PCR technique. Then the PCR reaction system was optimized and evaluated. HSV in swab specimens from patients with genital herpes was detected by real-time PCR. The real-time PCR assay showed good specificity for detection and typing of HSV, with good linear range (5×10(2)~5×10(8) copies/ml, r=0.997), a sensitivity of 5×10(2) copies/ml, and good reproducibility (intra-assay coefficients of variation 2.29% and inter-assay coefficients of variation 4.76%). 186 swab specimens were tested for HSV by real-time PCR, and the positive rate was 23.7% (44/186). Among the 44 positive specimens, 8 (18.2%) were positive for HSV-1 with a viral load of 8.5546×10(6) copies/ml and 36 (81.2%) were positive for HSV-2 with a viral load of 1.9861×10(6) copies/ml. It is concluded that the real-time PCR is a specific, sensitive and rapid method for the detection and typing of HSV, which can be widely used in clinical diagnosis of GH.

Indexed as

detectionGenital herpesherpes simplex virusreal-time polymerase chain reactiontyping

Identifiers

PMID26770492
PMCPMC4694392
OpenAlexW2428369804

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.