ArticleHeart rhythm2016
Tetanizing prepulse: A novel strategy to mitigate implantable cardioverter-defibrillator shock-related pain.
Article in Heart rhythm, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 8 citations in OpenAlex.
- Reduced motion external defibrillation: Reduced subject motion with equivalent defibrillation efficiency validated in swine.Heart rhythm · 2022Article
- High-energy external defibrillation and transcutaneous pacing during MRI: feasibility and safety.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2019Article
- Innovations in Clinical Cardiac Electrophysiology: Challenges and Upcoming Solutions in 2018 and Beyond.The Journal of innovations in cardiac rhythm management · 2017Review
- A Novel Defibrillation Tool: Percutaneously Delivered, Partially Insulated Epicardial Defibrillation.JACC. Clinical electrophysiology · 2017Article
Corrections and comments
- Commented on by
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundSkeletal muscle activation has been implicated as the source of pain associated with implantable cardioverter-defibrillator shocks. We hypothesized that the skeletal muscle response to defibrillatory shocks could be attenuated with a tetanizing prepulse immediately before biphasic shock delivery.
objectiveThe purpose of this study was to test the ability of tetanizing prepulses to reduce the skeletal muscle activation associated with defibrillation.
methodsSeven adult pigs were studied. A left ventricular coil and subcutaneous dummy can in the right thorax were used to deliver either pure biphasic waveforms or test waveforms consisting of a tetanizing pulse of high-frequency alternating current (HFAC) ramped to an amplitude of 5-100 V over 0.25-1 second, immediately followed by a biphasic shock of approximately 9 J (ramped HFAC and biphasic [rHFAC+B]). We used limb acceleration and rate of force development as surrogate measures of pain. Test and control waveforms were delivered in sinus rhythm and induced ventricular fibrillation to test defibrillation efficacy.
resultsDefibrillation threshold energy was indistinguishable between rHFAC+B and pure biphasic shocks. Peak acceleration and rate of force development were reduced by 72% ± 7% and 71% ± 22%, respectively, with a 25-V, 1-second rHFAC+B waveform compared with pure biphasic shocks. Notably, rHFAC+B with a 9-J biphasic shock produced significantly less skeletal muscle activation than a 0.1-J pure biphasic shock.
conclusionA putative source of implantable cardioverter-defibrillator shock-related pain can be mitigated using a tetanizing prepulse followed by biphasic shock. Human studies will be required to assess true pain reduction with this approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.