Evidence map›Paper›PMID 26762247›Full record

ArticleBMC oral health2016

Intraoral photobiomodulation-induced orthodontic tooth alignment: a preliminary study.

Timothy Shaughnessy, Alpdogan Kantarci, Chung How Kau, Darya Skrenes, Sanjar Skrenes, Dennis Ma

5 registry-linked trialsOpen access · goldAbstract readControlled Clinical Trial
In one paragraph

Article in BMC oral health, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 5 registered trials, which are not on this map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
5.7field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT02267837 nacompletednot on this map

OrthoPulse™ and Its Effect on the Rate of Orthodontic Tooth Alignment: A Pilot Feasibility Study.

TypeinterventionalSponsorBiolux Research Holdings, Inc.Ran2012 to 2013Enrolled20ConditionsMalocclusionArmsOrthoPulse™
NCT02954133 naunknown statusnot on this map

The Effect of OrthoPulse™ Photobiomodulation on Tooth Movement and Treatment Time When Used With Invisalign Treatment

TypeinterventionalSponsorBiolux Research Holdings, Inc.Ran2016 to 2019Enrolled167ConditionsMalocclusionArmsInvisalign (7 day), Invisalign (5 day), OrthoPulse, Invisalign (3.5 day)
NCT03202355 naterminatednot on this mapstarted 2017, after this paper: background citation

The Effect of OrthoPulse Photobiomodulation on the Rate of Tooth Movement During Alignment With Fixed Appliances

TypeinterventionalSponsorBiolux Research Holdings, Inc.Ran2017 to 2019Enrolled10ConditionsMalocclusionArmsFixed Appliance Orthodontic Treatment, OrthoPulse™
NCT03683017 naunknown statusnot on this mapstarted 2017, after this paper: background citation

OrthoPulse 2.0 and 2.1 Product Evaluation and Assessing Clinical Effectiveness: A Feasibility Study

TypeinterventionalSponsorBiolux Research Holdings, Inc.Ran2017 to 2020Enrolled35ConditionsMalocclusionArmsOrthoPulse 2.0, OrthoPulse 2.1, Invisalign 3.5 Day Wear, Fixed Orthodontic Appliances (Braces)
NCT05469451 naunknown statusnot on this mapstarted 2022, after this paper: background citation

Effect of Diode Laser (940nm) on Total Relief of Dental Crowding and Pain Perception in Orthodontics: Randomized Clinical Trial (RCT)

TypeinterventionalSponsorFundación Universitaria CIEORan2022 to 2022Enrolled50ConditionsLow Level Laser Therapy, Pain, Crowding, ToothArmsLow level laser therapy
3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it, 59 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Trial
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Effect of light-emitting photobiomodulation therapy on the rate of orthodontic tooth movement : A randomized controlled clinical trial.Journal of orofacial orthopedics = Fortschritte der Kieferorthopadie : Organ/official journal Deutsche Gesellschaft fur Kieferorthopadie · 2023
    Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Timothy ShaughnessyShaughnessy Orthodontics, 4330 Johns Creek Parkway, Suite 500, Suwanee, GA, USA. str8tth@me.com.
Alpdogan KantarciDepartment of Applied Oral Health Sciences, Forsyth Institute, 245 First Street, Cambridge, MA, USA. akantarci@forsyth.org.
Chung How KauDepartment of Orthodontics, Faculty of Dentistry, University of Alabama, 1919 7th Ave S, SDB 305, Birmingham, AL, USA. ckau@uab.edu.
Darya SkrenesBiolux Research Ltd, 220-825 Powell St, Vancouver, B.C, Canada. d.skrenes@bioluxresearch.com.
Sanjar SkrenesBiolux Research Ltd, 220-825 Powell St, Vancouver, B.C, Canada. sskrenes@gmail.com.
Dennis MaBiolux Research Ltd, 220-825 Powell St, Vancouver, B.C, Canada. dennis@data-analysis.ca.
Novant Health Forsyth Medical Center · USUniversity of Alabama · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNumerous strategies have been proposed to decrease orthodontic treatment time. Photobiomodulation (PBM) has previously been demonstrated to assist in this objective. The aim of this study was to test if intraoral PBM increases the rate of tooth alignment and reduces the time required to resolve anterior dental crowding.

methodsNineteen orthodontic subjects with Class I or Class II malocclusion and Little's Irregularity Index (LII) ≥ 3 mm were selected from a pool of applicants, providing 28 total arches. No cases required extraction. The test group (N = 11, 18 arches, 10 upper, 8 lower) received daily PBM treatment with an intraoral LED device (OrthoPulse™, Biolux Research Ltd.) during orthodontic treatment, while the control group (N = 8, 10 arches, 3 upper, 7 lower) received only orthodontic treatment. The PBM device exposed the buccal side of the gums to near-infrared light with a continuous 850-nm wavelength, generating an average daily energy density of 9.5 J/cm(2). LII was measured at the start (T0) of orthodontic treatment until alignment was reached (T1, where LII ≤ 1 mm). The control group was mostly bonded with 0.018-in slot self-ligating SPEED brackets (Hespeler Orthodontics, Cambridge, ON. Canada), while conventionally-ligating Ormco Mini-Diamond twins were used on the PBM group (Ormco, Glendora, Calif. USA). Both groups progressed through alignment with NiTi arch-wires from 0.014-in through to 0.018-in (Ormco), with identical arch-wire changes. The rate of anterior alignment, in LII mm/week, and total treatment time was collected for both groups. Cox proportional hazards models were used to compare groups and while considering age, sex, ethnicity, arch and degree of crowding.

resultsThe mean alignment rate for the PBM group was significantly higher than that of the control group, with an LII change rate of 1.27 mm/week (SD 0.53, 95 % CI ± 0.26) versus 0.44 mm/week (SD 0.20, 95 % CI ± 0.12), respectively (p = 0.0002). The treatment time to alignment was significantly smaller for the PBM group, which achieved alignment in 48 days (SD 39, 95 % CI ± 39), while the control group took 104 days (SD 55, 95 % CI ±19, p = 0.0053) on average. These results demonstrated that intraoral PBM increased the average rate of tooth movement by 2.9-fold, resulting in a 54 % average decrease in alignment duration versus control. The average PBM compliance to daily treatments was 93 % during alignment.

conclusionsUnder the limitations of this study, the findings suggest that intraoral PBM could be used to decrease anterior alignment treatment time, which could consequently decrease full orthodontic treatment time. However, due to its limitations, further research in the form of a large, randomized trial is needed.

trial registrationClinicalTrials.gov NCT02267837 . Registered 10 October 2014.

Indexed as

HumansMalocclusionOrthodontic BracketsOrthodontic WiresPhototherapyRadiation DosageTime FactorsTooth Movement Techniques

Identifiers

PMID26762247
PMCPMC4711021
OpenAlexW2239979838

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.