Evidence map›Paper›PMID 26762179›Full record

ArticleRadiation oncology (London, England)2016

Twin machines validation for VMAT treatments using electronic portal-imaging device: a multicenter study.

P Fenoglietto, M Khodri, D Nguyen, F Josserand-Pietri, N Aillères

Open access · goldAbstract readMulticenter StudyValidation Study
In one paragraph

Article in Radiation oncology (London, England), 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 4 institutions in 1 country.

P FenogliettoDépartement d'Oncologie Radiothérapie, Institut régional du Cancer de Montpellier (ICM), 208 rue des Apothicaires, F-34298, Montpellier, Cedex 5, France. pascal.fenoglietto@icm.unicancer.fr.
M KhodriDépartement d'Oncologie Radiothérapie, Institut de Cancérologie de la Loire (ICL), Saint Etienne, France. mustapha.khodri@icloire.fr.
D NguyenService de radiothérapie, Groupe ORLAM, Mâcon, France. nguyen.daniel@yahoo.fr.
F Josserand-PietriService de radiothérapie, Groupe ORLAM, Villeurbanne, France. florentin.jp@gmail.com.
N AillèresDépartement d'Oncologie Radiothérapie, Institut régional du Cancer de Montpellier (ICM), 208 rue des Apothicaires, F-34298, Montpellier, Cedex 5, France. norbert.ailleres@icm.unicancer.fr.
Centre de Radiothérapie Bayard · FRInstitut de Recherche en Cancérologie de Montpellier · FRInstitute Cancer De La Loire Lucien Neuwirth · FRInstitut Regional du Cancer de Montpellier

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo verify the accuracy of volumetric arc therapy (VMAT) using the RapidArc™ device when switching patients from one single linear accelerator (linac) to a paired energy and mechanics "twin" linac without reoptimization of the original treatment plan. PATIENTS AND

methodsFour centers using 8 linacs were involved in this study. Seventy-four patients previously treated with the 6MV photon RapidArc™ technique were selected for analysis, using 242 measurements. In each institution, all patients were planned on linac A, and their plans were verified both on linac A and on the twin linac B. Verifications were done using the amorphous silicium electronic portal imager (EPID) of the linacs and were analyzed with the EpiQa software (Epidos, Bratislavia, Slovakia). The gamma index formalism was used for validation with a double threshold of 3 % and 3 mm with a measurement resolution of 0.39 mm/pixel, and a smoothed resolution of approximately 2.5 mm.

resultsThe number of points passing the gamma criteria between the measured and computed doses was 94.79 ± 2.57 % for linac A and 94.61 ± 2.46 % for linac B. Concerning the smoothed measurement analysis, 98.67 ± 1.26 % and 98.59 ± 1.20 % points passing the threshold were obtained for linacs A and B, respectively. The difference between the 2 dose matrices acquired on the EPID was very small, with 99.92 ± 0.06 % of the points passing the criteria.

conclusionFor linacs sharing the same mechanical and energy parameters, this study tends to indicate that patients may be safely switched from treatment with one linac to treatment with its twin linac using the same VMAT plan.

Indexed as

AlgorithmsCalibrationElectronicsFemaleFranceHead and Neck NeoplasmsHumansMaleNeoplasmsNormal DistributionParticle AcceleratorsPelvic NeoplasmsQuality Assurance, Health CareRadiographic Image Interpretation, Computer-AssistedRadiotherapy, Image-GuidedRadiotherapy, Intensity-Modulated

Identifiers

PMID26762179
PMCPMC4712460
OpenAlexW2233524117

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.