Evidence map›Paper›PMID 26757892›Full record

ArticleScientific reports2016

Two-Photon Excitation STED Microscopy with Time-Gated Detection.

Iván Coto Hernández, Marco Castello, Luca Lanzanò, Marta d'Amora, Paolo Bianchini, Alberto Diaspro, Giuseppe Vicidomini

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
9.1field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 33 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Iván Coto HernándezNanoscopy, Nanophysics, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genoa, Italy.
Marco CastelloNanoscopy, Nanophysics, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genoa, Italy.
Luca LanzanòNanoscopy, Nanophysics, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genoa, Italy.
Marta d'AmoraNanoscopy, Nanophysics, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genoa, Italy.
Paolo BianchiniNanoscopy, Nanophysics, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genoa, Italy.
Alberto DiasproNanoscopy, Nanophysics, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genoa, Italy.
Giuseppe VicidominiNanoscopy, Nanophysics, Istituto Italiano di Tecnologia, Via Morego 30, 16163 Genoa, Italy.
Italian Institute of Technology · ITUniversity of Genoa · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We report on a novel two-photon excitation stimulated emission depletion (2PE-STED) microscope based on time-gated detection. The time-gated detection allows for the effective silencing of the fluorophores using moderate stimulated emission beam intensity. This opens the possibility of implementing an efficient 2PE-STED microscope with a stimulated emission beam running in a continuous-wave. The continuous-wave stimulated emission beam tempers the laser architecture's complexity and cost, but the time-gated detection degrades the signal-to-noise ratio (SNR) and signal-to-background ratio (SBR) of the image. We recover the SNR and the SBR through a multi-image deconvolution algorithm. Indeed, the algorithm simultaneously reassigns early-photons (normally discarded by the time-gated detection) to their original positions and removes the background induced by the stimulated emission beam. We exemplify the benefits of this implementation by imaging sub-cellular structures. Finally, we discuss of the extension of this algorithm to future all-pulsed 2PE-STED implementationd based on time-gated detection and a nanosecond laser source.

Indexed as

Cell LineHumansMicroscopy, FluorescenceMicrotubulesPhotonsSignal-To-Noise Ratio

Identifiers

PMID26757892
PMCPMC4725939
OpenAlexW2416052525

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked