Evidence map›Paper›PMID 26753534›Full record

SynthesisJournal of clinical monitoring and computing2017

Reproducibility of transpulmonary thermodilution cardiac output measurements in clinical practice: a systematic review.

Raphaël Giraud, Nils Siegenthaler, Paolo Merlani, Karim Bendjelid

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Journal of clinical monitoring and computing, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 24 citations in OpenAlex.

  1. Trial
  2. Do ScvOPhysiological reports · 2021
    Trial
  3. Observational
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Haemodynamic monitoring in acute heart failure - what you need to know.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2022
    Review
  10. Article
  11. Article
  12. Article
  13. Review
  14. Cardiac Output Monitoring in Preterm Infants.Frontiers in pediatrics · 2018
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Raphaël GiraudIntensive Care Service, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1211, Geneva 14, Switzerland. Raphael.Giraud@hcuge.ch.
Nils SiegenthalerIntensive Care Service, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1211, Geneva 14, Switzerland.
Paolo MerlaniIntensive Care Service, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1211, Geneva 14, Switzerland.
Karim BendjelidIntensive Care Service, Geneva University Hospitals, 4 Rue Gabrielle Perret-Gentil, 1211, Geneva 14, Switzerland.
University Hospital of Geneva · CHUniversity of Geneva · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Measuring cardiac output (CO) is an integral part of the diagnostic and therapeutic strategy in critically ill patients. During the last decade, the single transpulmonary thermodilution (TPTD) technique was implemented in clinical practice. The purpose of this paper was to systematically review and critically assess the existing data concerning the reproducibility of CO measured using TPTD (COTPTD). A total of 16 studies were identified to potentially be included in our study because these studies had the required information that allowed for calculating the reproducibility of COTPTD measurements. 14 adult studies and 2 pediatric studies were analyzed. In total, 3432 averaged CO values in the adult population and 78 averaged CO values in the pediatric population were analyzed. The overall reproducibility of COTPTD measurements was 6.1 ± 2.0 % in the adult studies and 3.9 ± 2.9 % in the pediatric studies. An average of 3 boluses was necessary for obtaining a mean CO value. Achieving more than 3 boluses did not improve reproducibility; however, achieving less than 3 boluses significantly affects the reproducibility of this technique. The present results emphasize that TPTD is a highly reproducible technique for monitoring CO in critically ill patients, especially in the pediatric population. Our findings suggest that obtaining a mean of 3 measurements for determining CO values is recommended.

Indexed as

Cardiac OutputAdultAlgorithmsChildFluid TherapyHumansModels, StatisticalMonitoring, PhysiologicReproducibility of ResultsThermodilutionCardiac outputPrecisionReproducibilityTranspulmonary thermodilution

Identifiers

PMID26753534
OpenAlexW2239999543

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked