Evidence map›Paper›PMID 26751849›Full record

Trial reportScientific reports2016

Simple and effective exercise design for assessing in vivo mitochondrial function in clinical applications using (31)P magnetic resonance spectroscopy.

Alison Sleigh, Victoria Lupson, Ajay Thankamony, David B Dunger, David B Savage, T Adrian Carpenter, Graham J Kemp

Open access · goldAbstract readClinical Trial
In one paragraph

Trial report in Scientific reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it, 19 citations in OpenAlex.

  1. NMR in biomedicine · 2025
    Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. HyperpolarizedRadiology · 2021
    Article
  11. Article
  12. MR compatible ergometers for dynamicJournal of applied biomedicine · 2019
    Review
  13. In-vivoAnalytical biochemistry · 2017
    Review
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Alison SleighWolfson Brain Imaging Centre, University of Cambridge School of Clinical Medicine, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK.
Victoria LupsonWolfson Brain Imaging Centre, University of Cambridge School of Clinical Medicine, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK.
Ajay ThankamonyDepartment of Paediatrics, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK.
David B DungerDepartment of Paediatrics, University of Cambridge, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK.
David B SavageUniversity of Cambridge Metabolic Research Laboratories, Wellcome Trust-Medical Research Council Institute of Metabolic Science, Cambridge, CB2 0QQ, UK.
T Adrian CarpenterWolfson Brain Imaging Centre, University of Cambridge School of Clinical Medicine, Cambridge Biomedical Campus, Cambridge, CB2 0QQ, UK.
Graham J KempMagnetic Resonance &Image Analysis Research Centre, Department of Musculoskeletal Biology and MRC - Arthritis Research UK Centre for Integrated research into Musculoskeletal Ageing, University of Liverpool, Liverpool, L69 3GE, UK.
University of Cambridge · GBUniversity of Liverpool · GBWellcome/MRC Institute of Metabolic Science · GB

Funding

Medical Research Council G0600717Medical Research Council G0701532Medical Research Council MC_UU_12012/5Wellcome Trust 091551
6 · The paper itself

Abstract

The growing recognition of diseases associated with dysfunction of mitochondria poses an urgent need for simple measures of mitochondrial function. Assessment of the kinetics of replenishment of the phosphocreatine pool after exercise using (31)P magnetic resonance spectroscopy can provide an in vivo measure of mitochondrial function; however, the wider application of this technique appears limited by complex or expensive MR-compatible exercise equipment and protocols not easily tolerated by frail participants or those with reduced mental capacity. Here we describe a novel in-scanner exercise method which is patient-focused, inexpensive, remarkably simple and highly portable. The device exploits an MR-compatible high-density material (BaSO4) to form a weight which is attached directly to the ankle, and a one-minute dynamic knee extension protocol produced highly reproducible measurements of post-exercise PCr recovery kinetics in both healthy subjects and patients. As sophisticated exercise equipment is unnecessary for this measurement, our extremely simple design provides an effective and easy-to-implement apparatus that is readily translatable across sites. Its design, being tailored to the needs of the patient, makes it particularly well suited to clinical applications, and we argue the potential of this method for investigating in vivo mitochondrial function in new cohorts of growing clinical interest.

Indexed as

AdultAnkleDatabases as TopicExerciseFemaleHumansHydrogen-Ion ConcentrationLipodystrophyMagnetic Resonance SpectroscopyMaleMitochondriaPhosphocreatinePhosphorusReproducibility of ResultsPhosphocreatinePhosphorus

Identifiers

PMID26751849
PMCPMC4707472
OpenAlexW2238343886

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.