Evidence map›Paper›PMID 26746711›Full record

ArticleApplied and environmental microbiology2016

Loop-Mediated Isothermal Amplification (LAMP) for Rapid Detection and Quantification of Dehalococcoides Biomarker Genes in Commercial Reductive Dechlorinating Cultures KB-1 and SDC-9.

Yogendra H Kanitkar, Robert D Stedtfeld, Robert J Steffan, Syed A Hashsham, Alison M Cupples

Abstract readComparative StudyEvaluation Study
In one paragraph

Article in Applied and environmental microbiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Microbiological Sensing Technologies: A Review.Bioengineering (Basel, Switzerland) · 2018
    Review
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yogendra H KanitkarDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, USA.
Robert D StedtfeldDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, USA.
Robert J SteffanBiotechnology Development and Applications Group, CB&I Federal Services, LLC, Lawrenceville, New Jersey, USA.
Syed A HashshamDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, USA.
Alison M CupplesDepartment of Civil and Environmental Engineering, Michigan State University, East Lansing, Michigan, USA cupplesa@egr.msu.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Real-time quantitative PCR (qPCR) protocols specific to the reductive dehalogenase (RDase) genes vcrA, bvcA, and tceA are commonly used to quantify Dehalococcoides spp. in groundwater from chlorinated solvent-contaminated sites. In this study, loop-mediated isothermal amplification (LAMP) was developed as an alternative approach for the quantification of these genes. LAMP does not require a real-time thermal cycler (i.e., amplification is isothermal), allowing the method to be performed using less-expensive and potentially field-deployable detection devices. Six LAMP primers were designed for each of three RDase genes (vcrA, bvcA, and tceA) using Primer Explorer V4. The LAMP assays were compared to conventional qPCR approaches using plasmid standards, two commercially available bioaugmentation cultures, KB-1 and SDC-9 (both contain Dehalococcoides species). DNA was extracted over a growth cycle from KB-1 and SDC-9 cultures amended with trichloroethene and vinyl chloride, respectively. All three genes were quantified for KB-1, whereas only vcrA was quantified for SDC-9. A comparison of LAMP and qPCR using standard plasmids indicated that quantification results were similar over a large range of gene concentrations. In addition, the quantitative increase in gene concentrations over one growth cycle of KB-1 and SDC-9 using LAMP was comparable to that of qPCR. The developed LAMP assays for vcrA and tceA genes were validated by comparing quantification on the Gene-Z handheld platform and a real-time thermal cycler using DNA isolated from eight groundwater samples obtained from an SDC-9-bioaugmented site (Tulsa, OK). These assays will be particularly useful at sites subject to bioaugmentation with these two commonly used Dehalococcoides species-containing cultures.

Indexed as

Gene DosageGenes, BacterialBacteriological TechniquesBiomarkersChloroflexiGroundwaterNucleic Acid Amplification TechniquesTime FactorsBiomarkers

Identifiers

PMID26746711
PMCPMC4784023

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.