Evidence map›Paper›PMID 26745963›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2016

A new wide-angle arthroscopic system: a comparative study with a conventional 30° arthroscopic system.

Kyunghwa Jung, Dong-Ju Kang, Aashay L Kekatpure, Arnold Adikrishna, Jaesung Hong, In-Ho Jeon

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Kyunghwa JungDepartment of Robotics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333, Techno-jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu, 711-873, Korea.
Dong-Ju KangMGB Endoscopy Co. Ltd, Seoul, Korea.
Aashay L KekatpureDepartment of Orthopedic Surgery, Asan Medical Center, School of Medicine, University of Ulsan, 86 Asanbyeongwon-gil, Songpa-gu, Seoul, 138-736, Korea.
Arnold AdikrishnaDepartment of Orthopedic Surgery, Asan Medical Center, School of Medicine, University of Ulsan, 86 Asanbyeongwon-gil, Songpa-gu, Seoul, 138-736, Korea.
Jaesung HongDepartment of Robotics Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333, Techno-jungang-daero, Hyeonpung-myeon, Dalseong-gun, Daegu, 711-873, Korea. jhong@dgist.ac.kr.
In-Ho JeonDepartment of Orthopedic Surgery, Asan Medical Center, School of Medicine, University of Ulsan, 86 Asanbyeongwon-gil, Songpa-gu, Seoul, 138-736, Korea. jeonchoi@gmail.com.
Asan Medical Center · KRDaegu Gyeongbuk Institute of Science and Technology · KRUniversity of Ulsan · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare users' hand movements in performing validated shoulder arthroscopic tasks between a 30° and a wide-angle arthroscopic system, using phantom models with an optical motion analysis system.

methodsTwelve orthopaedic residents were enrolled and randomly allocated into two groups. In order to compensate for any learning effect, a Latin square counterbalancing technique was used. An optical motion analysis system was used with markers affixed to pre-designed sites; each participant conducted four validated shoulder arthroscopic tasks using both arthroscopic systems. Each participant was instructed to perform the experiment three times with each arthroscope. The time taken, total path length, number of movements, and average acceleration were analysed.

resultsSignificant differences were observed for the time taken, number of movements, and average acceleration between the two arthroscopic systems (P < 0.05 for all). However, the time taken was not significant. The mean total path length measured 53 ± 38 cm with the 30° arthroscope, while the mean with the wide-angle arthroscope was significantly shorter, at 36 ± 22 cm. The mean number of movements with the 30° and wide-angle arthroscopes were 1974 ± 1305 and 1233 ± 990, respectively, while the average accelerations were 2.6 ± 1.3 and 1.2 ± 0.6 cm/s(2), respectively. The mean time taken was 13 % faster when using the wide-angle arthroscopic system, although this was not statistically significant.

conclusionThe wide-angle arthroscopic system improved the arthroscope manoeuvre in terms of the total path length, number of movements, and average acceleration required for experimental arthroscopy. This system may help surgeons triangulate the arthroscope and surgical instruments during surgery by expanding the field of view.

Indexed as

ArthroscopesTask Performance and AnalysisArthroscopyHumansModels, AnatomicShoulder Joint30° arthroscopeMotion analysisShoulder arthroscopyWide-angle arthroscope

Identifiers

PMID26745963
OpenAlexW2226496437

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.