Evidence map›Paper›PMID 26730114›Full record

ArticleIndian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine2015

Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study.

Sumant Prabhudesai, Amruta Kanjani, Isha Bhagat, Karnam G Ravikumar, Bala Ramachandran

Open access · bronzeAbstract read
In one paragraph

Article in Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.

  1. Guideline
  2. Review
  3. Article
  4. Continuous Glucose Monitoring in the Hospital.Endocrinology and metabolism (Seoul, Korea) · 2021
    Review
  5. Consensus Statement on Inpatient Use of Continuous Glucose Monitoring.Journal of diabetes science and technology · 2017
    Article
  6. Article
  7. Real-time continuous glucose monitoring in children with critical illness - do we need it?Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2015
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Sumant PrabhudesaiRoyal Manchester Children's Hospital, Manchester, UK.
Amruta KanjaniColumbia Asia Hospital, Ahmedebad, Gujrat, India.
Isha BhagatPD Hinduja National Hospital and Medical Research Centre, Mumbai, India.
Karnam G RavikumarKanchi Kamakoti CHILDS Trust Hospital, Chennai, Tamil Nadu, India.
Bala RamachandranKanchi Kamakoti CHILDS Trust Hospital, Chennai, Tamil Nadu, India.
Kanchi Kamakoti CHILDS Trust Hospital · INColumbia Asia · INRoyal Manchester Children's Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsThe aim of this prospective, observational study was to determine the accuracy of a real-time continuous glucose monitoring system (CGMS) in children with septic shock. SUBJECTS AND

methodsChildren aged 30 days to 18 years admitted to the Pediatric Intensive Care Unit with septic shock were included. A real-time CGMS sensor was used to obtain interstitial glucose readings. CGMS readings were compared statistically with simultaneous laboratory blood glucose (BG).

resultsNineteen children were included, and 235 pairs of BG-CGMS readings were obtained. BG and CGMS had a correlation coefficient of 0.61 (P < 0.001) and a median relative absolute difference of 17.29%. On Clarke's error grid analysis, 222 (94.5%) readings were in the clinically acceptable zones (A and B). When BG was < 70, 70-180, and > 180 mg/dL, 44%, 100%, and 76.9% readings were in zones A and B, respectively (P < 0.001). The accuracy of CGMS was not affected by the presence of edema, acidosis, vasopressors, steroids, or renal replacement therapy. On receiver operating characteristics curve analysis, a CGMS reading <97 mg/dL predicted hypoglycemia (sensitivity 85.2%, specificity 75%, area under the curve [AUC] =0.85). A reading > 141 mg/dL predicted hyperglycemia (sensitivity 84.6%, specificity 89.6%, AUC = 0.87).

conclusionCGMS provides a fairly, accurate estimate of BG in children with septic shock. It is unaffected by a variety of clinical variables. The accuracy over extremes of blood sugar may be a concern. We recommend larger studies to evaluate its use for the early detection of hypoglycemia and hyperglycemia.

Indexed as

Childrencontinuous glucose monitoring systemseptic shock

Identifiers

PMID26730114
PMCPMC4687172
OpenAlexW2265773766

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked