Evidence map›Paper›PMID 26728484›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2016

Comparison of linear motion perception thresholds in vestibular migraine and Menière's disease.

Tatiana Bremova, Arla Caushaj, Matthias Ertl, Ralf Strobl, Nicolina Böttcher, Michael Strupp, Paul R MacNeilage

Abstract readComparative Study
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed.

  1. Article
  2. Intra-individual consistency of vestibular perceptual thresholds.Attention, perception & psychophysics · 2024
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Head-centric computing for vestibular stimulation under head-free conditions.Frontiers in bioengineering and biotechnology · 2023
    Article
  9. Article
  10. Article
  11. New Frontiers in Managing the Dizzy Patient.Otolaryngologic clinics of North America · 2021
    Review
  12. Article
  13. Review
  14. Review
  15. Review
  16. Article
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Tatiana BremovaGerman Center for Vertigo and Balance Disorders, University Hospital Munich, Marchioninistrasse 15, 81377, Munich, Germany. Tatiana.Bremova@med.uni-muenchen.de.
Arla CaushajGerman Center for Vertigo and Balance Disorders, University Hospital Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Matthias ErtlGerman Center for Vertigo and Balance Disorders, University Hospital Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Ralf StroblGerman Center for Vertigo and Balance Disorders, University Hospital Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Nicolina BöttcherGerman Center for Vertigo and Balance Disorders, University Hospital Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Michael StruppGerman Center for Vertigo and Balance Disorders, University Hospital Munich, Marchioninistrasse 15, 81377, Munich, Germany.
Paul R MacNeilageGerman Center for Vertigo and Balance Disorders, University Hospital Munich, Marchioninistrasse 15, 81377, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Linear motion perceptual thresholds (PTs) were compared between patients with Menière's disease (MD) and vestibular migraine (VM). Twenty patients with VM, 27 patients with MD and 34 healthy controls (HC) were examined. PTs for linear motion along the inter-aural (IA), naso-occipital axes (NO), and head-vertical (HV) axis were measured using a multi-axis motion platform. Ocular and cervical vestibular evoked myogenic potentials (o/c VEMP) were performed and the dizziness handicap inventory (DHI) administered. In order to discriminate between VM and MD, we also evaluated the diagnostic accuracy of applied methods. PTs depended significantly on the group tested (VM, MD and HC), as revealed by ANCOVA with group as the factor and age as the covariate. This was true for all motion axes (IA, HV and NO). Thresholds were highest for MD patients, significantly higher than for all other groups for all motion axes, except for the IA axis when compared with HC group suggesting decreased otolith sensitivity in MD patients. VM patients had thresholds that were not different from those of HC, but were significantly lower than those of the MD group for all motion axes. The cVEMP p13 latencies differed significantly across groups being lowest in VM. There was a statistically significant association between HV and NO thresholds and cVEMP PP amplitudes. Diagnostic accuracy was highest for the IA axis, followed by cVEMP PP amplitudes, NO and HV axes. To conclude, patients with MD had significantly higher linear motion perception thresholds compared to patients with VM and controls. Except for reduced cVEMP latency, there were no differences in c/oVEMP between MD, VM and controls.

Indexed as

AdultAnalysis of VarianceCase-Control StudiesDiagnosis, DifferentialDizzinessFemaleHumansMaleMeniere DiseaseMiddle AgedMigraine DisordersMotion PerceptionOtolithic MembraneSensory ThresholdsVertigoVestibular Evoked Myogenic PotentialsDiagnostic accuracyMenière’s diseaseOtolith functionPerception thresholdsSacculeUtricleVestibular migraine

Identifiers

PMID26728484
PMCPMC5014886

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked