Real-time magnetic resonance imaging-guided transcatheter aortic valve replacement.

Justin G Miller, Ming Li, Dumitru Mazilu, Tim Hunt, Keith A Horvath

Open access · bronzeAbstract read
In one paragraph

Article in The Journal of thoracic and cardiovascular surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Review
  4. Article
  5. Improved passive catheter tracking with positive contrast for CMR-guided cardiac catheterization using partial saturation (pSAT).Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2017
    Article
  6. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Justin G MillerCardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Md.
Ming LiCardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Md.
Dumitru MaziluCardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Md.
Tim HuntCardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Md.
Keith A HorvathCardiothoracic Surgery Research Program, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Md. Electronic address: horvathka@mail.nih.gov.
National Institutes of Health · USNational Heart Lung and Blood Institute · US

Funding

NHLBI Animal Program DivisionZIGHL006020 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI CLARK, TANNIA · 2009 to 2025
$47.3M
MRI Guided Robotic Cardiac SurgeryZ01HL005073 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI HORVATH, KEITH A · 2006 to 2008
$1.0M
Intramural NIH HHS Z01 HL005073
6 · The paper itself

Abstract

objectivesTo demonstrate the feasibility of Real-time magnetic resonance imaging (rtMRI) guided transcatheter aortic valve replacement (TAVR) with an active guidewire and an MRI compatible valve delivery catheter system in a swine model.

methodsThe CoreValve system was minimally modified to be MRI-compatible by replacing the stainless steel components with fluoroplastic resin and high-density polyethylene components. Eight swine weighing 60-90 kg underwent rtMRI-guided TAVR with an active guidewire through a left subclavian approach.

resultsTwo imaging planes (long-axis view and short-axis view) were used simultaneously for real-time imaging during implantation. Successful deployment was performed without rapid ventricular pacing or cardiopulmonary bypass. Postdeployment images were acquired to evaluate the final valve position in addition to valvular and cardiac function.

conclusionsOur results show that the CoreValve can be easily and effectively deployed through a left subclavian approach using rtMRI guidance, a minimally modified valve delivery catheter system, and an active guidewire. This method allows superior visualization before deployment, thereby allowing placement of the valve with pinpoint accuracy. rtMRI has the added benefit of the ability to perform immediate postprocedural functional assessment, while eliminating the morbidity associated with radiation exposure, rapid ventricular pacing, contrast media renal toxicity, and a more invasive procedure. Use of a commercially available device brings this rtMRI-guided approach closer to clinical reality.

Indexed as

BioprosthesisAnimalsAortic Valve StenosisDisease Models, AnimalFemaleHeart Valve ProsthesisMagnetic Resonance Imaging, CineMaleMinimally Invasive Surgical ProceduresOperative TimePostoperative ComplicationsProsthesis DesignProsthesis FailureRandom AllocationSensitivity and SpecificitySwineMedtronic CoreValvereal-time magnetic resonance imageswine animal modeltranscatheter aortic valve replacement

Identifiers

PMID26725711
PMCPMC4834228
OpenAlexW2204029607

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.