Observational studyJournal of artificial organs : the official journal of the Japanese Society for Artificial Organs2016
Comparison of subcutaneous and intravenous continuous glucose monitoring accuracy in an operating room and an intensive care unit.
Observational study in Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 2 syntheses or guidelines pooled it, 25 citations in OpenAlex.
- Perioperative use and accuracy of continuous glucose monitoring: A systematic review.Diabetes, obesity & metabolism · 2025Pooled it
- Continuous peri-operative glucose monitoring in noncardiac surgery: A systematic review.European journal of anaesthesiology · 2025Pooled it
- Artificial pancreas: the past and the future.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2025Review
- A case of perioperative artificial pancreas therapy for a patient with esophageal cancer with type 1 diabetes.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2024Article
- Continuous Glucose Monitoring in the Intensive Care Unit.Journal of diabetes science and technology · 2023Article
- Head-to-head comparison of two continuous glucose monitoring systems on a cardio-surgical ICU.Journal of clinical monitoring and computing · 2019Article
- Current status and issues of the artificial pancreas: abridged English translation of a special issue in Japanese.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2018Review
- A prolonged run-in period of standard subcutaneous microdialysis ameliorates quality of interstitial glucose signal in patients after major cardiac surgery.Scientific reports · 2018Article
- Glucose Management during Insulinoma Resection Using Real-Time Subcutaneous Continuous Glucose Monitoring.Case reports in anesthesiology · 2018Article
- Accuracy and Time Delay of Glucose Measurements of Continuous Glucose Monitoring and Bedside Artificial Pancreas During Hyperglycemic and Euglycemic Hyperinsulinemic Glucose Clamp Study.Journal of diabetes science and technology · 2017Article
- Current topics in glycemic control by wearable artificial pancreas or bedside artificial pancreas with closed-loop system.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although we have used an intravenous continuous glucose monitor for blood glucose management, a previous study reported that a subcutaneous continuous glucose monitor was also reliable for use in critically ill patients. The aim of this study was to compare the subcutaneous and intravenous continuous glucose monitors. This was an observational trial (UMIN-CTR, ID:000013338). We included patients who were admitted to our intensive care units (ICU) after hepato-biliary pancreatic surgery. Continuous blood glucose measurement was performed from the beginning of the operation to ICU discharge using the intravenous continuous monitor STG-55 (Nikkiso, Tokyo, Japan) and the subcutaneous continuous monitor iPro2 (Medtronic Japan, Tokyo, Japan). The STG-55 measured the glucose level in real time, and the iPro2 measured this every 5 min. We compared glucose levels obtained using the two devices every 5 min using a Bland-Altman plot and a regression analyses. A total of 3592 comparative samples in 15 cases were analyzed. The mean glucose level measured using the STG-55 was 139 ± 21 mg/dl, and that measured using the iPro2 was 144 ± 31 mg/dl. A linear regression line had the equation of the form y = 0.225x + 106. The coefficient of determination was 0.11, and the F-test significance level was set as p < 0.01. The mean of the differences was -5.2 mg/dl, with a 95 % agreement limit of -67 to + 57 mg/dL. The percent error was 44 %. In conclusion, the current study suggests that subcutaneous and intravenous continuous glucose monitoring was not highly correlated during either surgery or ICU stay.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials