Evidence map›Paper›PMID 26717236›Full record

ArticlePloS one2015

A Novel Approach for Dynamic Testing of Total Hip Dislocation under Physiological Conditions.

Sven Herrmann, Daniel Kluess, Michael Kaehler, Robert Grawe, Roman Rachholz, Robert Souffrant, János Zierath, Rainer Bader, Christoph Woernle

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
0.6field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Exploration of the Advanced VIVOBioengineering (Basel, Switzerland) · 2024
    Article
  3. Article
  4. Narrative Review of the Mechanism of Hip Prosthesis Dislocation and Methods to Reduce the Risk of Dislocation.Medical science monitor : international medical journal of experimental and clinical research · 2022
    Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Sven HerrmannDepartment of Orthopaedics, University Medicine Rostock, Rostock, Germany.
Daniel KluessDepartment of Orthopaedics, University Medicine Rostock, Rostock, Germany.
Michael KaehlerChair of Technical Dynamics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Rostock, Germany.
Robert GraweChair of Technical Dynamics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Rostock, Germany.
Roman RachholzChair of Technical Dynamics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Rostock, Germany.
Robert SouffrantDepartment of Orthopaedics, University Medicine Rostock, Rostock, Germany.
János ZierathChair of Technical Dynamics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Rostock, Germany.
Rainer BaderDepartment of Orthopaedics, University Medicine Rostock, Rostock, Germany.
Christoph WoernleChair of Technical Dynamics, Faculty of Mechanical Engineering and Marine Technology, University of Rostock, Rostock, Germany.
University of Rostock · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Constant high rates of dislocation-related complications of total hip replacements (THRs) show that contributing factors like implant position and design, soft tissue condition and dynamics of physiological motions have not yet been fully understood. As in vivo measurements of excessive motions are not possible due to ethical objections, a comprehensive approach is proposed which is capable of testing THR stability under dynamic, reproducible and physiological conditions. The approach is based on a hardware-in-the-loop (HiL) simulation where a robotic physical setup interacts with a computational musculoskeletal model based on inverse dynamics. A major objective of this work was the validation of the HiL test system against in vivo data derived from patients with instrumented THRs. Moreover, the impact of certain test conditions, such as joint lubrication, implant position, load level in terms of body mass and removal of muscle structures, was evaluated within several HiL simulations. The outcomes for a normal sitting down and standing up maneuver revealed good agreement in trend and magnitude compared with in vivo measured hip joint forces. For a deep maneuver with femoral adduction, lubrication was shown to cause less friction torques than under dry conditions. Similarly, it could be demonstrated that less cup anteversion and inclination lead to earlier impingement in flexion motion including pelvic tilt for selected combinations of cup and stem positions. Reducing body mass did not influence impingement-free range of motion and dislocation behavior; however, higher resisting torques were observed under higher loads. Muscle removal emulating a posterior surgical approach indicated alterations in THR loading and the instability process in contrast to a reference case with intact musculature. Based on the presented data, it can be concluded that the HiL test system is able to reproduce comparable joint dynamics as present in THR patients.

Indexed as

Computer SimulationHip DislocationArthroplasty, Replacement, HipBiomechanical PhenomenaHip JointHumansLubricationModels, TheoreticalMusclesReproducibility of Results

Identifiers

PMID26717236
PMCPMC4696831
OpenAlexW2204367512

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.