Trial reportPloS one2015
Hydrogel-Forming Microneedle Arrays Allow Detection of Drugs and Glucose In Vivo: Potential for Use in Diagnosis and Therapeutic Drug Monitoring.
Trial report in PloS one, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 58 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
58 citing papers in PubMed, 165 citations in OpenAlex.
- Vacuum-Assisted Microneedle Platforms for Dermal Interstitial Fluid Sampling.Pharmaceutics · 2026Review
- Biomimetic Material Selection for Therapeutic Microneedles: An Analytic Hierarchy Process-Based Multi-Criteria Evaluation.Polymers · 2026Article
- Enhanced extraction of human interstitial fluid using microneedles and laser-induced fluid recruitment.iScience · 2025Article
- Design of Hydrogel Microneedle Arrays for Physiology Monitoring of Farm Animals.Micromachines · 2025Article
- Fabrication and mechanical/biological evaluations of dissolving bird-bill microneedle arrays.Drug delivery and translational research · 2025Article
- Fabrication of porous polymeric microneedles: a concise overview.RSC advances · 2025Review
- Hydrogel-Forming Microneedles and Applications in Interstitial Fluid Diagnostic Devices.Advanced healthcare materials · 2025Review
- Self-Extracting Dextran-Based Hydrogel Microneedle Arrays with an Interpenetrating Bioelectroenzymatic Sensor for Transdermal Monitoring with Matrix Protection.Advanced healthcare materials · 2025Article
- Lateral Flow-Based Skin Patch for Rapid Detection of Protein Biomarkers in Human Dermal Interstitial Fluid.ACS sensors · 2024Article
- Advances in Polysaccharide-Based Microneedle Systems for the Treatment of Ocular Diseases.Nano-micro letters · 2024Review
- Advances in microneedles for transdermal diagnostics and sensing applications.Mikrochimica acta · 2024Review
- Swellable Microneedles in Drug Delivery and Diagnostics.Pharmaceuticals (Basel, Switzerland) · 2024Review
- Advancements in Skin-Mediated Drug Delivery: Mechanisms, Techniques, and Applications.Advanced healthcare materials · 2024Review
- Review
- Dissolving and Swelling Hydrogel-Based Microneedles: An Overview of Their Materials, Fabrication, Characterization Methods, and Challenges.Gels (Basel, Switzerland) · 2023Review
- Advances and Prospects for Hydrogel-Forming Microneedles in Transdermal Drug Delivery.Biomedicines · 2023Review
- Hydrogel-Forming Microneedles with Applications in Oral Diseases Management.Materials (Basel, Switzerland) · 2023Review
- Development of a novel microneedle platform for biomarker assessment of atopic dermatitis patients.Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI) · 2023Article
- Response Surface Methodology for Optimization of Hydrogel-Forming Microneedles as Rapid and Efficient Transdermal Microsampling Tools.Gels (Basel, Switzerland) · 2023Article
- Advances in dermatological application of GelMA hydrogel microneedles.Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI) · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
We describe, for the first time the use of hydrogel-forming microneedle (MN) arrays for minimally-invasive extraction and quantification of drug substances and glucose from skin in vitro and in vivo. MN prepared from aqueous blends of hydrolysed poly(methyl-vinylether-co-maleic anhydride) (11.1% w/w) and poly(ethyleneglycol) 10,000 daltons (5.6% w/w) and crosslinked by esterification swelled upon skin insertion by uptake of fluid. Post-removal, theophylline and caffeine were extracted from MN and determined using HPLC, with glucose quantified using a proprietary kit. In vitro studies using excised neonatal porcine skin bathed on the underside by physiologically-relevant analyte concentrations showed rapid (5 min) analyte uptake. For example, mean concentrations of 0.16 μg/mL and 0.85 μg/mL, respectively, were detected for the lowest (5 μg/mL) and highest (35 μg/mL) Franz cell concentrations of theophylline after 5 min insertion. A mean concentration of 0.10 μg/mL was obtained by extraction of MN inserted for 5 min into skin bathed with 5 μg/mL caffeine, while the mean concentration obtained by extraction of MN inserted into skin bathed with 15 μg/mL caffeine was 0.33 μg/mL. The mean detected glucose concentration after 5 min insertion into skin bathed with 4 mmol/L was 19.46 nmol/L. The highest theophylline concentration detected following extraction from a hydrogel-forming MN inserted for 1 h into the skin of a rat dosed orally with 10 mg/kg was of 0.363 μg/mL, whilst a maximum concentration of 0.063 μg/mL was detected following extraction from a MN inserted for 1 h into the skin of a rat dosed with 5 mg/kg theophylline. In human volunteers, the highest mean concentration of caffeine detected using MN was 91.31 μg/mL over the period from 1 to 2 h post-consumption of 100 mg Proplus® tablets. The highest mean blood glucose level was 7.89 nmol/L detected 1 h following ingestion of 75 g of glucose, while the highest mean glucose concentration extracted from MN was 4.29 nmol/L, detected after 3 hours skin insertion in human volunteers. Whilst not directly correlated, concentrations extracted from MN were clearly indicative of trends in blood in both rats and human volunteers. This work strongly illustrates the potential of hydrogel-forming MN in minimally-invasive patient monitoring and diagnosis. Further studies are now ongoing to reduce clinical insertion times and develop mathematical algorithms enabling determination of blood levels directly from MN measurements.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.