ArticleOpen forum infectious diseases2015
Legionellosis Outbreak Associated With a Hotel Fountain.
Article in Open forum infectious diseases, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- A Hybrid Occupational Risk Assessment ofMicroorganisms · 2026Article
- Evolution and main causes of the rising legionellosis incidence in the United States.PLOS global public health · 2026Article
- Iron-depleting nutritional immunity controls extracellular bacterial replication in Legionella pneumophila infections.Nature communications · 2024Article
- Correlation between bacterial microbiome andMicrobiology spectrum · 2024Article
- Surveillance ofMicroorganisms · 2022Article
- Food products as potential carriers of SARS-CoV-2.Food control · 2021Review
- Persistence ofPathogens (Basel, Switzerland) · 2020Article
- A Snapshot of the Prevalence and Molecular Diversity ofPathogens (Basel, Switzerland) · 2020Article
- Multistate analysis of prospective Legionnaires' disease cluster detection using SaTScan, 2011-2015.PloS one · 2019Article
- Outbreaks of Legionnaires' Disease and Pontiac Fever 2006-2017.Current environmental health reports · 2018Review
- Legionnaires' Disease: Clinicoradiological Comparison of Sporadic Versus Outbreak Cases.Clinical medicine insights. Circulatory, respiratory and pulmonary medicine · 2017Article
- A case of legionella pneumonia caused by home use of continuous positive airway pressure.SAGE open medical case reports · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background. In August 2012, the Chicago Department of Public Health (CDPH) was notified of acute respiratory illness, including 1 fatality, among a group of meeting attendees who stayed at a Chicago hotel during July 30-August 3, 2012. Suspecting Legionnaires' disease (LD), CDPH advised the hotel to close their swimming pool, spa, and decorative lobby fountain and began an investigation. Methods. Case finding included notification of individuals potentially exposed during July 16-August 15, 2012. Individuals were interviewed using a standardized questionnaire. An environmental assessment was performed. Results. One hundred fourteen cases were identified: 11 confirmed LD, 29 suspect LD, and 74 Pontiac fever cases. Illness onsets occurred July 21-August 22, 2012. Median age was 48 years (range, 22-82 years), 64% were male, 59% sought medical care (15 hospitalizations), and 3 died. Relative risks for hotel exposures revealed that persons who spent time near the decorative fountain or bar, both located in the lobby were respectively 2.13 (95%, 1.64-2.77) and 1.25 (95% CI, 1.09-1.44) times more likely to become ill than those who did not. Legionella pneumophila serogroup 1 was isolated from samples collected from the fountain, spa, and women's locker room fixtures. Legionella pneumophila serogroup 1 environmental isolates and a clinical isolate had matching sequence-based types. Hotel maintenance records lacked a record of regular cleaning and disinfection of the fountain. Conclusions. Environmental testing identified Legionella in the hotel's potable water system. Epidemiologic and laboratory data indicated the decorative fountain as the source. Poor fountain maintenance likely created favorable conditions for Legionella overgrowth.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.