SynthesisWorld journal of gastroenterology2015
Endoscopic stenting for inoperable malignant biliary obstruction: A systematic review and meta-analysis.
Synthesis in World journal of gastroenterology, 2015. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 49 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Partially Covered Metal Stents Efficacy in the Biliary Drainage of Malignant Extra-hepatic Biliary Obstruction, a Multicentric Randomized Trial
Palliative Treatment of Distal Malignant Biliary Obstruction by Endoscopic Stents: Uncovered, Partially Covered, or Fully Covered Metal Stents: A Prospective Randomized Multicenter Study
Who cites it
49 citing papers in PubMed, 1 synthesis or guideline pooled it, 111 citations in OpenAlex.
- Plastic vs. Self-Expandable Metal Stents for Palliation in Malignant Biliary Obstruction: A Series of Meta-Analyses.The American journal of gastroenterology · 2017Pooled it
- Clinical outcomes of plastic versus self-expanding metal stents in malignant hilar biliary obstruction.Surgical endoscopy · 2026Article
- Impact of Sphincterotomy on Suprapapillary Inside Stent Patency in Unresectable Malignant Hilar Biliary Obstruction: A Multicenter Cohort Study.Endoscopy international open · 2026Article
- Novel self-expandable metal stent with dumbbell-shape and spiral cover to prevent stent-related cholecystitis.Endoscopy · 2025Article
- Efficacy of double half-pigtail plastic stents for endoscopic biliary drainage of acute calculous cholangitis.Clinical endoscopy · 2025Article
- Technological Advances and Medical Applications of Implantable Electronic Devices: From the Heart, Brain, and Skin to Gastrointestinal Organs.Biosensors · 2025Review
- Article
- Endoscopic Biliary Drainage in Malignant Biliary Strictures: A Prospective Analysis Based on Real-World Data.Gastroenterology research · 2025Article
- The Palliation of Unresectable Pancreatic Cancer: Evolution from Surgery to Minimally Invasive Modalities.Journal of clinical medicine · 2025Review
- Risk factors of early dysfunction after switching from plastic to metal stents in malignant extrahepatic biliary obstruction.Journal of the Chinese Medical Association : JCMA · 2025Article
- Endoscopic biliary drainage for distal bile duct obstruction due to pancreatic cancer.Clinical endoscopy · 2025Review
- An Approach to and Treatment of Indeterminate Biliary Strictures: A Comprehensive Review of the Literature.Journal of clinical medicine · 2024Review
- Intraductal radiofrequency ablation plus biliary stent versus stent alone for malignant biliary obstruction: a systematic review and meta-analysis.Endoscopy international open · 2024Review
- Article
- Factors associated with patency of self-expandable metal stents in malignant biliary obstruction.BMC gastroenterology · 2023Article
- Review
- Pathophysiological consequences and treatment strategy of obstructive jaundice.World journal of gastrointestinal surgery · 2023Review
- Article
- Comparison of therapeutic efficacy and treatment costs of self-expandable metal stents and plastic stents for management of malignant biliary obstruction.BMC gastroenterology · 2023Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimTo analyze through meta-analyses the benefits of two types of stents in the inoperable malignant biliary obstruction.
methodsA systematic review of randomized clinical trials (RCT) was conducted, with the last update on March 2015, using EMBASE, CINAHL (EBSCO), MEDLINE, LILACS/CENTRAL (BVS), SCOPUS, CAPES (Brazil), and gray literature. Information of the selected studies was extracted in sight of six outcomes: primarily regarding dysfunction, complication and re-intervention rates; and secondarily costs, survival, and patency time. The data about characteristics of trial participants, inclusion and exclusion criteria and types of stents were also extracted. The bias was mainly assessed through the JADAD scale. This meta-analysis was registered in the PROSPERO database by the number CRD42014015078. The analysis of the absolute risk of the outcomes was performed using the software RevMan, by computing risk differences (RD) of dichotomous variables and mean differences (MD) of continuous variables. Data on RD and MD for each primary outcome were calculated using the Mantel-Haenszel test and inconsistency was qualified and reported in χ (2) and the Higgins method (I (2)). Sensitivity analysis was performed when heterogeneity was higher than 50%, a subsequent assay was done and other findings were compiled. Student's t-test was used for the comparison of weighted arithmetic means regarding secondary outcomes.
resultsInitial searching identified 3660 studies; 3539 were excluded through title, repetition, and/or abstract, while 121 studies were fully assessed and were excluded mainly because they did not compare self-expanding metal stents (SEMS) and plastic stents (PS), leading to thirteen RCT selected, with 13 articles and 1133 subjects meta-analyzed. The mean age was 69.5 years old, that were affected mostly by bile duct (proximal) and pancreatic tumors (distal). The preferred SEMS diameter used was the 10 mm (30 Fr) and the preferred PS diameter used was 10 Fr. In the meta-analysis, SEMS had lower overall stent dysfunction compared to PS (21.6% vs 46.8%, P < 0.00001) and fewer re-interventions (21.6% vs 56.6%, P < 0.00001), with no difference in complications (13.7% vs 15.9%, P = 0.16). In the secondary analysis, the mean survival rate was higher in the SEMS group (182 d vs 150 d, P < 0.0001), with a higher patency period (250 d vs 124 d, P < 0.0001) and a lower cost per patient (4193.98 vs 4728.65 Euros, P < 0.0985).
conclusionSEMS are associated with lower stent dysfunction, lower re-intervention rates, better survival, and higher patency time. Complications and costs showed no difference.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.