ArticleACS applied materials & interfaces2016
Mutually-Reactive, Fluorogenic Hydrocyanine/Quinone Reporter Pairs for In-Solution Biosensing via Nanodroplet Association.
Article in ACS applied materials & interfaces, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 24 citations in OpenAlex.
- Article
- Systematic design and evaluation of aptamers for VEGF and PlGF biomarkers of Preeclampsia.BMC biotechnology · 2024Article
- One Single Tube Reaction of Aptasensor-Based Magnetic Sensing System for Selective Fluorescent Detection of VEGF in Plasma.Biosensors · 2023Article
- Article
- A One-Step Electrochemical Aptasensor Based on Signal Amplification of Metallo Nanoenzyme Particles for Vascular Endothelial Growth Factor.Frontiers in bioengineering and biotechnology · 2022Article
- Base amount-dependent fluorescence enhancement for the assay of vascular endothelial growth factor 165 in human serum using hairpin DNA-silver nanoclusters and oxidized carbon nanoparticles.Mikrochimica acta · 2020Article
- Recent advances in aptamer-based sensors for breast cancer diagnosis: special cases for nanomaterial-based VEGF, HER2, and MUC1 aptasensors.Mikrochimica acta · 2020Review
- Design and Application of Stimulus-Responsive Droplets and Bubbles Stabilized by Phospholipid Monolayers.Current opinion in colloid & interface science · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
Mutually reactive, fluorogenic molecules are presented as a simple and novel technique for in-solution biosensing. The hypothesis behind this work was that aggregating droplets into close proximity would cause rapid mixing of their contents. To take advantage of this effect, a novel pair of fluorogenic redox molecules were designed to remain in lipid-stabilized oil droplets but mix once aggregated. First, the hydrophobic cyanine dye 1,1'-dioctadecyl-3,3,3'3'-tetramethylindocarbocyanine perchlorate (DiI) was reduced with sodium borohydride to form a nonfluorescent analog (HDiI). Hydrophobic quinone derivatives were then screened as oxidizing agents, and it was found that p-fluoranil oxidized nonfluorescent HDiI back to fluorescent DiI. Next, HDiI and p-fluoranil were loaded into NEOBEE oil nanodroplets of average diameter 600 nm that were stabilized by a monolayer of 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC), 1,2-distearoyl-sn-glycero-3-phosphoethanolamine (DSPE)-polyethylene glycol (PEG), and DSPE-PEG-biotin. Addition of streptavidin caused aggregation of droplets and the appearance of red fluorescent aggregates within 30 min. Next, Nanoparticle Tracking Analysis was used to record the fluorescence of the droplets and their aggregates. By integrating the fluorescence emission of the tracked droplets, streptavidin could be detected down to 100 fM. Finally, the droplets were reformulated to sense for vascular endothelial growth factor (VEGF), a biomarker for tumor metastasis. Using anti-VEGF aptamers attached to DSPE-PEG incorporated into the nanodroplet monolayer, VEGF could also be detected down to 100 fM.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.